Download Print this page

Emerson Rosemount 2051HT Quick Start Manual page 24

Hygienic pressure transmitterwith foundation fieldbus protoco
Hide thumbs Also See for Rosemount 2051HT:

Advertisement

Quick Start Guide
be taken into account during installation and use to prevent impact
and friction.
Certificate: 2041384 (HART/Fieldbus/PROFIBUS
Standards: ANSI/ISA 12.27.01-2003, CSA Std. C22.2 No.142-M1987, CSA
Markings:
4.5.2
I6 Canada Intrinsic Safety
Certificate: 2041384
Standards: CSA Std. C22.2 No. 142 - M1987, CSA Std. C22.2 No. 213 -
Markings:
4.6
Europe
4.6.1
I1 ATEX Intrinsic Safety
Certificate:
Standards:
Markings:
Table 4-1: Input Parameters
Parameter
Voltage U
Current I
Power P
Capacitance C
Inductance L
24
Std. C22.2. No.157-92
IS CL I, DIV 1, GP A, B, C, D; CL II, DIV 1, GP E, F, G; Class III; DIV
1 when connected per Rosemount drawing 02051-1009;
Class I, Zone 0; AEx ia IIC T4; NI CL 1, DIV 2, GP A, B, C, D;
T4(-50 °C ≤ T
M1987, CSA Std. C22.2 No. 157 - 92, CSA Std. C22.2 No. 213
- M1987, ANSI/ISA 12.27.01 – 2003, CAN/CSA-E60079-0:07,
CAN/CSA-E60079-11:02
Intrinsically safe for Class I, Division 1, Groups A, B, C, and D
when connected in accordance with Rosemount drawing
02051-1008. Ex ia IIC T3C. Single Seal. Enclosure Type 4X
Baseefa08ATEX0129X
EN60079-0:2012+A11:2013, EN60079-11:2012
Ex II 1 G Ex ia IIC T4 Ga (–60 °C ≤ T
HART
30 V
i
200 mA
i
1 W
i
0.012 μF
i
0 mH
i
≤ +70 °C); Type 4x
a
Fieldbus/PROFIBUS
30 V
300 mA
1.3 W
0 μF
0 mH
November 2019
®
)
≤ +70 °C)
a
Rosemount 2051HT

Advertisement

loading