Heat & Glo HST-48D Owner's Manual

Heat & glo wood burning fireplace owner's manual
Hide thumbs Also See for HST-48D:
Table of Contents

Advertisement

Quick Links

Models:
HST-48D
Wood Burning Fireplace
Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re. Overfi ring will void your
warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
Installation and service of this fi replace
should be performed by qualifi ed personnel.
Hearth & Home Technologies suggests NFI
certifi ed or factory-trained professionals, or
technicians supervised by an
NFI certifi ed professional.
NOTICE
DO NOT DISCARD THIS MANUAL
Read, understand
and follow these
instructions for safe
i n s t a l l a t i o n a n d
operation.
Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
Hot screen/mesh and glass doors will cause burns.
DO NOT touch screen/mesh or glass doors until
cooled
NEVER allow children to touch screen/mesh or glass
doors
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other
fl ammable materials away.
WARNING
Fire Risk
For use with solid wood fuel or decorative
gas appliance only.
DO NOT install unvented gas logs.
HOT SURFACES!
Screen/mesh, glass doors
and other surfaces are hot
during operation AND cool
down.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo HST-48D

  • Page 1 • For use with solid wood fuel or decorative technicians supervised by an gas appliance only. NFI certifi ed professional. • DO NOT install unvented gas logs. Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 2: Congratulations

    ADJUST DAMPER TO THE FULLY OPEN POSITION. 1915 W. SAUNDERS ST., MT. PLEASANT, IA 52641. Note: An arrow ( ) found in the text signifies change in content.  Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 3: Table Of Contents

    Tools and Supplies Needed G. Fireplace System Requirements 13 Reference Materials H. Inspect Fireplace and Components A. Fireplace Dimensions B. Optional Components C. Service Parts  D. Contact Information Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 4: Warranty

    Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645C 12-29-10 Page 1 of 2 Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 5 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645C 12-29-10 Page 2 of 2 Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 6: Listing And Code Approvals

    NOTICE: This fireplace is tested and approved as a decorative fireplace. It should not be factored as a primary heat source in residential heating calculations. Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 7: User Guide

    Firescreen Wood Fuel (not shown) Section 2.M. close Damper Section 2.E. Handle Hearth Glass Doors (not shown) Section 2.H. Clear Space Section 2.L. Figure 2.1 General Operating Parts Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 8: Seasoned Wood

    CAUTION! Odors and vapors released during initial operation may be irritating to sensitive individuals. Open windows for air circulation. Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 9: Glass Doors

    BEFORE lighting fi re. 48 in. (1219 mm) Clear Space 12 in. (305 mm) Front of Fireplace Clear Space Sides of Fireplace (from the FP opening) Figure 2.3 Clear Space Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 10: Wood Fuel

    Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 11: Maintenance And Service

    Section TR11/TR11T TCT1175 ST1175 TR444/TR442 Terra Cotta ST475 Round Termination Cap Square Termination Cap Termination Cap Available US only DT SERIES Figure 3.1 Chimney & Termination Cap Cleaning Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 12: Check Firebox Refractory

    • Light deposits Use household glass cleaner • Heavy deposits Use wood ash on damp cloth or, Use commercial fireplace glass cleaner (consult with your dealer) Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 13: Troubleshooting Guide

    Add glass doors to slow down air flow. Overdrafting Check for correct vent height; too much vertical height creates overdrafting. Check location of vent termination (refer to chimney assembly section). Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 14: Getting Started

    (1.83m) off (Section 11) ground level. Hearth extension Outside (Section 11) combustion air Factory-built fireplace (Section 7) Protective metal hearth strip(s) (Section 7) Figure 5.1 Typical Fireplace System Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 15: Design And Installation Considerations

    Tight sealing construction of the structure • Mechanical exhausting devices NOTICE: Hearth & Home Technologies Inc. recommends • Improper location of the chimney the use of direct vent fireplaces in basements. Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 16: Locating Fireplace & Chimney

    • Below adjacent structure Recommended: • Insulated exterior chase • Lower roof line • Avoid outside wall in cooler climates Windward Leeward Multi-level Roofs Figure 5.2 Recommended Chimney Locations Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 17: Tools And Supplies Needed

    Outside Air Hood (sold separately) Duct (required for outside air installation, sold separately) • Chimney Air Kit (required in Canada) • Chimney System (required, sold separately) • Termination Cap (required, sold separately) Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 18: Framing & Clearances

    • Clearances • Mantel Projections • Fireplace Dimensions 12 in. (305 mm) min. to perpendicular 64 in. wall. (1626 mm) Figure 6.1 Fireplace Locations (Framing dimensions shown) Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 19: Clearances

    1219 mm 0 in. to floor Figure 6.2 Clearances to Combustible Materials Note: Chimney air kit and 11-10 in./279-254 mm adapter are not shown, but are required in Canada. Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 20: Sidewalls/Surrounds

    Note: Fireplace Header cannot be positioned until after the fireplace assembly is in place. 48 in. (1219 mm) 27 in. (686 mm) Figure 6.4 Framing the Fireplace Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 21: Installation Of Fireplace

    • Check fireplace opening for square to ensure proper fit of glass doors. Measure diagonals of fireplace opening to make sure they are equal. Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 22 Figure 7.4 Outside Combustion Air Placement Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 23: Install Outside Air Kit

    Blockages could cause combustion air starvation. Flexible Duct (not supplied) Outside Air Plate Outside Air Assembly Hood 2 Wire Ties Figure 7.5 Outside Air Installation Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 24: Chimney Assembly

    Ceiling firestops are required where chimney passes through ceiling or floor Figure 8.1 Typical Chimney System - Guidelines for Chimney System Installation Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 25: Chimney Requirements

    58-7/8 in. Canada. SLA10 16-3/4 (1495 mm) a,b,c,f Effective * Dimensions reflect effective height. Height Figure 8.2 Chimney Requirements (refer to list in Sect. 5.A.) Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 26: Using Offsets/Returns

    2511 Proper assembly of air cooled chimney parts results in an overlap of chimney joints of 1-1/4 in. (32 mm). Effective length is built into this table. Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 27: Assemble Chimney Sections

    Vertical straight runs of chimney must be supported every 35 ft (10.7 m). D. Install Chimney Air Kit • Required in Canada. • Follow instructions provided with this accessory. Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 28: Install Ceiling Firestops

    Note: Use same dimensional lumber for framing home (use 600° F sealant). ceiling firestop and joists. Catalog # FS538 FS540 Figure 8.5 Installing the Ceiling Firestop Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 29: Install Attic Insulation Shield

    17 in. (432 mm) diameter 6 Tabs bent in 90° Insulation Insulation 13 in. Ceiling Firestop Pipe (330 mm) Figure 8.8 Install Attic Insulation Shield (firestop below ceiling) Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 30: Cut Out Hole In Roof

    • Caulk the flashing plate and roof junction as well as the vertical seam on the flashing. All nail heads must be caulked with a roofing sealant. Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 31: Chimney Termination Requirements

    In a staggered installation with both gas and wood terminations, the wood termination cap must be higher than the gas termination cap. Figure 8.10 Multiple Chimney Locations Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 32: Chase Installations

    Failure to prevent contact between insulation or other Insulation Insulation materials and chimney system may cause overheating False Ceiling False Ceiling and fire. Chimney Figure 9.1 Chase Assembly Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 33: Install Fireplace & Chimney

    CAUTION! DO NOT caulk the pipe to the chase Galvanized Chase Top top collar. • Caulk all seams to prevent leaks. • Refer to Figure 9.4. Figure 9.3 Chase Top Construction Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 34: Install Termination Cap

    4 3/4 in. (121 mm) maximum Chase Chimney Pipe Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Figure 9.6 Installing an ST1175/ST475 Square Termination Cap Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 35 2 in. (51 mm) 7 in. (178 mm) Chase Chimney Pipe Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Figure 9.7 Installing a TCT1175 Terra Cotta Cap Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 36: Shrouds

    737 x 737 584 x 584 Min. Opening Width 26 x 26 20 x 20 660 x 660 508 x 508 Figure 10.2 Open Top Shroud Dimensions Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 37 34 x 34 34 x 34 864 x 864 864 x 864 Min. Height Above Radiation Shield Min. Opening Width Min. Opening Height Figure 10.4 Roofed Style Shroud Dimensions Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 38: Finishing

    Common Brick 0.20 5-1/8 in. Ceramic Tile 12.50 0.08 12-1/4 in. Armstrong™ Privacy Guard Plus 0.46 2.18 1/2 in. Marble 14.3-20.0 0.07-0.05 14-5/8 in. - 20-3/8 in. Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 39: Finishing Material

    2 in. (51 mm) Figure 11.3 Decorative Facing Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 40: Combustible Mantel

    47 in. [1194 mm] width of fireplace 12 in. 12 in. [305 mm] [305 mm] Figure 11.5 Mantel Leg or Wall Projections (acceptable on both sides of opening) Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 41: Accessories

    Repack beyond 4 in. (102 mm) insulation from fireplace side. knockout 4 in. (102 mm) Figure 12.1 Gas Line Installation Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 42: Reference Materials

    Reference Materials A. Fireplace Dimensions Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 43: Optional Components

    20 in. (508 mm) 1/2 in. (13 mm) HX4 Hearth Extension DM8042 Bi-fold Glass Doors See your Heat & Glo dealer for a complete listing of optional components. Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 44 (527 mm) 5-1/4 in. (133 mm) 4 in. (102 mm) 13 in. Outside Diameter (330 mm) 13 in. (330 mm) SL11/SL4 Vent Stabilizer CAK5A Chimney Air Kit Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 45 13 in. 15-3/4 in. (330 mm) (400 mm) CB576 Chimney Joint Band TR11/TR444 - Round Termination Cap 10 3/4 in. 26 in. TR-TVK TR Top Vent Kit CT-11A Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 46 72 in. 36 in. DTO134 (1829 mm) (914 mm) 13-3/8 in. (340 mm) DTO146 22.7 1168 DTS134 21.18 2 in. (51 mm) DTS146 21.18 CT56 Chase Top 1168 Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...
  • Page 47: Service Parts

    C. Service Parts Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L• 7/12...
  • Page 48: Contact Information

    Heat & Glo • HST-48D US-CAN • 4012-040 • Rev L • 7/12...

Table of Contents