Flush or inset installation of the hob:

Depending on whether you would like the hob to be inset or flush fit
into the worktop, the cutout requirements are slightly different:
Inset installation
5.5 mm
Flush installation
5.5 mm
Fig.9
IMPORTANT: When fitting the hob into the worktop, you should never
seal it in place with silicone sealant or similar means. The appliance
may need to be removed at a later date for servicing.
The appliance should be installed with sufficient ventilation so
ambient temperatures (e.g. if an oven is installed nearby) do
not exceed 60°C. Such temperatures will cause issues with the
controls.
2 mm
2 mm
6 mm
520
780
750
520
780
750 490
784
51
490
51
R.4
R.6
524
33