3. Other Alarm Visual and Audible Indicators

Operational Mode
normal (standby)
test (button press when
no alarm condition is
present)
Smoke alarm Memory
(unit has experienced a
smoke alarm event within
the last hour)
Smoke alarm Hush Mode,
(Hush®
control)
Locate
Smoke alarm Hush Mode
canceled
initiating alarm,
(Multiple alarms in an
interconnected system)
6
Visual Indications
AC power: Green LED on continuously
during light conditions, or blink every 60
sec during dark conditions.
DC power: Green LED blink approx
every 60 sec.
4 patterns of Red/Amber/Green.
Test: Red LED blinks in time with
alarm pattern. Safety light will briefly
illuminate on model P4010LACS-WCA.
Green LED fade on/off at test complete
Red and Amber LED alternate on 1 sec,
every 10 sec.
Red LED blinks every 2 sec.
None
None
Green LED blinks once per sec indicating
that this is the unit initiating the alarm
in an interconnected, multiple alarm,
system.
Audible Indications
Button press sound
Voice: "Testing, this is very loud.
Press now to cancel test. 5, 4, 3, 2, 1."
3 long beeps, Voice "Fire!", 3 long
beeps, Voice "Test Complete,"
Power on/reset sound.
Voice "Test Canceled" if button
pushed before test sequence
begins.
After button push: "Smoke previously
detected" only on the initiating
alarm unit.
After button push: "Hush Mode
Activated." Smoke alarm pattern
stops. (If there is too much smoke to
allow Hush: Voice "Too Much Smoke,
Alarm cannot be Hushed" Smoke
alarm pattern continues.)
After button push on non-initiating
unit, only initiating unit continues
alarm pattern.
Voice message "Hush Mode
Canceled."
Unit in Smoke alarm mode.
Action/Note:
Perform Test/Hush button press
once a week to verify proper alarm
operation
* Push/release button before the
countdown ends to cancel test.
Push test button to clear Alarm
Memory. NOTE: standard test
sequence will follow. (Push/release
button again to cancel test).
This feature is to be used only
when a known alarm condition,
such as smoke from cooking,
activates the alarm.
Use this to quickly locate the alarm
source and determine if alarm is
nuisance or real.
When smoke levels drop below the
alarm threshold, the voice message
"Hush Mode Canceled" will occur .
During alarm, the initiating alarm
red blink will be interrupted by a
green blink.