3. Other Alarm Visual and Audible Indicators

Operational Mode
Normal (standby)
Test (button press when no
alarm condition is present, or
alarm is not in out of box or
enrollment mode)
Smoke or CO Alarm Memory
(unit has experienced a smoke
or CO alarm event within the
last hour)
Smoke Alarm Hush Mode,
(SMART HUSH®
CONTROL)
CO alarm reset
Smoke Alarm Hush Mode
Canceled
Initiating Alarm,
(Multiple alarms in an
interconnected system)
Weather & Intruder Alert
(1)
6
(1) Requires additional devices and/or permissions in app to enable these features.
Visual Indications
AC power: Green LED on continuously during
light conditions, or blink every 60 sec during dark
conditions.
DC power: Green LED blink approx every 60 sec.
• 4 patterns of Red/Amber/Green.
• Test: Red LED blinks in time with alarm
pattern.
• Green LED fade on/off at test complete
Red and Amber LED alternate on 1 sec,
every 10 sec.
Red LED blinks every 2 sec.
None
None
Green LED blinks once per sec indicating
that this is the unit initiating the alarm in an
interconnected, multiple alarm, system.
Red LED flashes every sec.
Audible Indications
• Button press sound
• Voice: "Testing, this is very loud.
Press now to cancel test. 5, 4, 3, 2, 1."
• 3 long beeps, Voice "Fire!",
3 long beeps, 4 quick beeps, Voice
"Warning, Carbon Monoxide," 4
quick beeps, Voice "Test Complete,"
Power on/reset sound.
• Voice "Test Canceled" if button
pushed before test sequence begins.
After button push, voice "Smoke
previously detected" or "Carbon
Monoxide previously detected" only on
the initiating alarm unit.
After button push, voice "Hush Mode
Activated." Smoke alarm pattern
stops.
(If there is too much smoke to allow
Hush: Voice "Too Much Smoke, Alarm
cannot be Hushed" Smoke alarm
pattern continues.)
After button push: CO alarm pattern
stops.
Voice "Hush Mode Canceled."
Unit in either Smoke or CO alarm
mode.
One long beep, 5 sec pause, Voice:
"Weather emergency in vicinity" OR
one long beep every other sec, voice
every 10 sec "Intruder detected."
Action/Note:
Perform button press once a week
to verify proper alarm operation
* Push/release button before the
countdown ends to cancel test.
Push button to clear Alarm
Memory. NOTE: standard test
sequence will follow. (Push/release
button again to cancel test).
This feature is to be used only
when a known alarm condition,
such as smoke from cooking,
activates the alarm.
Unit is confirming if CO is present
or if it experienced a nuisance
situation. Re-alarm means danger.
Move to fresh air and call 911.
When smoke levels drop below the
alarm threshold, the voice message
will occur .
During alarm, the initiating alarm
red blink will be interrupted by a
green blink.
Take appropriate precautions.