Resetting A Device's Wireless Settings - Kidde P4010ACS-WCA User Manual

Hardwire photoelectric smoke alarm with voice and wireless interconnect
Table of Contents

Advertisement

F. pick tHe inStaLLed deVice
Press and hold the button on the INSTALLED device for 5 SECONDS
until you hear two beeps. Release button. "Sonar" ping will stop.
Device will announce that setup is complete and the number of
connected devices.
G. proceed to WirinG inStrUctionS in Section 10.

9.3 Resetting a Device's Wireless Settings

If you encounter an issue at any point during the wireless network setup process, you may reset the device by
following the directions below.
a. beGin reSet
Press and hold the button on the device for 8-9 seconds until you
hear 3 beeps. Release button. You will hear the words "Resetting
wireless settings."
b. concLUde reSet
Light ring will flash green once and then it will pulse red. You will hear
the words, "Ready to connect, follow quick start instructions."
Device has been reset.
See Section 9.1 to begin set-up of a new wireless alarm network,
or Section 9.2 for adding this device to an existing alarm network.
If no further steps are taken within 15 minutes of resetting the unit's wireless settings, a voice
note:
prompt "No devices found, not connected" will be heard once, and the wireless function will turn off. The
unit will then perform as a standard hardwired alarm. See Section 9.2 for adding this device to an existing
alarm network.
16
"Setup
complete!"
Installed Device
Figure 9.2-E
"Resetting
wireless
settings."
Figure 9.3-A
"Ready to
connect, follow
Quick Start
instructions."
Figure 9.3-B
Added Device
Hold for
8-9 seconds

Advertisement