Other Alarm Visual And Audible Indicators - Kidde 30CUA10-V User Manual

Combination photoelectric smoke & carbon monoxide alarm with hardwire interconnect & voice
Table of Contents

Advertisement

If problems are identified during this inspection, have the equipment serviced
immediately. Note any combustion equipment not inspected by the technician and consult the
manufacturer's instructions, or contact the manufacturer directly for more information
about CO safety and the equipment. Make sure that motor vehicles are not, or have not been,
operating in a garage attached or adjacent to the residence. Never restart the source of a CO
problem until it has been corrected. Never ignore the sound of the alarm!

3. Other Alarm Visual And Audible Indicators

Operational Mode
normal (standby)
test (button press when
no alarm condition is
present)
(note: test is very loud,
stand a few feet away.)
Smoke or co Alarm
Memory (unit has
experienced a smoke or
co alarm event, or has
detected 100ppm co
or greater.)
tM
Smoke Alarm Hush
Mode
co Alarm Reset
6
Visual Indications
AC power: Green LED on
continuously.
DC power: Green LED blinks
approx every 60 sec.
Red LED blinks in time with
alarm pattern.
Smoke: Red LED blinks
every 15 sec.
CO: 2 red LED blinks
every 15 sec.
Red LED blinks every 2 sec.
(only on the initiating alarm)
None.
Audible Indications
• Single beep.
• 3 long beeps, voice "Fire!,"
3 long beeps, 4 quick beeps,
voice "Warning, Carbon Monoxide,"
4 quick beeps.
Af ter button push, voice
"Smoke previously detected"
or "Carbon monoxide previ-
ously detected."
After button push, voice "Hush
Mode Activated." Smoke alarm
pattern stops. If there is too much
TM
smoke to allow Hush
, voice
"Too much smoke, alarm cannot
be hushed." (smoke alarm pattern
continues)
After button push: CO alarm
pattern stops.
Action/Note
Perform button press once a week
to verify proper alarm operation.
NOTE: Alarm memory is only
retained for 24 hrs.
Push button to clear Alarm
Memory.
This feature is to be used only
when a known alarm condition,
such as smoke from cooking,
activates the alarm. Push button
TM
during Hush
to clear Hush
and perform a test.
Unit is confirming if CO is present
or if it experienced a nuisance
situation. Re-alarm means danger.
Move to fresh air and call 911.
TM