Other Alarm Visual And Audible Indicators - Kidde 20SA10-V User Manual

Photoelectric smoke alarm with hardwire interconnect & voice
Table of Contents

Advertisement

3. Other Alarm Visual And Audible Indicators

Operational Mode
Normal (standby)
Test (button press when
no alarm condition is
present)
(Note: Test is very loud,
stand a few feet away.)
Smoke Alarm Memory
(unit has experienced a
smoke event.)
TM
Smoke Alarm Hush
Mode
Initiating Alarm
(multiple alarms in an
interconnected system)
6
Visual Indications
AC power: Green LED on
continuously.
DC power: Green LED blinks
approx every 60 sec.
Red LED blinks in time with
alarm pattern.
Red LED blinks
every 15 sec.
Red LED blinks every 2 sec.
(only on the initiating alarm)
Red LED blinks in time with
alarm pattern indicating that
this is the unit initiating the
alarm in an interconnected,
multiple alarm, system.
NOTE: It is possible for more
than one unit to detect a haz-
ard and become an initiating
alarm unit (Red LED blinking).
Audible Indications
• • Single beep.
• 3 long beeps, voice "Fire!,"
3 long beeps.
After button push, voice
"Smoke previously detected."
After button push, voice
"Hush Mode Activated."
Smoke alarm pattern stops.
If there is too much smoke to
TM
allow Hush
, voice "Too much
smoke, alarm cannot be hushed."
(smoke alarm pattern continues)
Unit in smoke alarm mode.
Action/Note
Perform button press once a week
to verify proper alarm operation.
NOTE: Alarm memory is only
retained for 24 hrs. Push button to
clear Alarm Memory.
This feature is to be used only when
a known alarm condition, such as
smoke from cooking, activates the
alarm. Push button during Hush
TM
clear Hush
and perform a test.
TM
to