Mitsubishi Electric FR-F 700 EC Instruction Manual page 129

Hide thumbs Also See for FR-F 700 EC:
Table of Contents

Advertisement

Extended parameters
Parameter
Name
RUN terminal
190
function selection
SU terminal
191
function selection
IPF terminal
192
function selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal
195
function selection
ABC2 terminal
196
function selection
232 to 239
Refer to Pr.4 to Pr.6.
240
Refer to Pr.72.
241
Refer to Pr.125 and Pr.126.
242, 243
Refer to Pr.73.
122
Incre
Initial
Range
ments
Value
0, 100: Inverter running
1, 101: Up to frequency
1
0
2, 102: Instantaneous power failure/
0 to 5, 7, 8,
10 to 19, 25,
3, 103: Overload alarm
26, 45 to 47,
4, 104: Output frequency detection
64, 70 to 78
5, 105: Second output frequency
1
1
90 to 96, 98,
99,
7, 107: Regenerative brake prealarm
100 to 105,
107, 108,
8, 108: Electronic thermal relay function
110 to 116,
1
2
125, 126,
10, 110: PU operation mode
145 to 147,
11, 111: Inverter operation ready
164, 170,
12, 112: Output current detection
190 to 196,
13, 113: Zero current detection
1
3
198, 199,
14, 114: PID lower limit
9999
15, 115: PID upper limit
16, 116: PID forward/reverse rotation
1
4
17, —: Commercial power-supply
18, —: Commercial power-supply
19, —: Commercial power-supply
1
99
25, 125: Fan fault output
26, 126: Heatsink overheat pre-alarm
45, 145: Inverter running and start
46, 146: During deceleration at
0 to 5, 7, 8,
47, 147: During PID control activated
10 to 19, 25,
64, 164: During retry
26, 45 to 47,
70, 170: PID output interruption
64, 70 to 78,
71: Commercial-power supply side motor 1
90, 91, 94 to
96, 98, 99,
72: Commercial-power supply side motor 2
100 to 105,
107, 108,
73: Commercial-power supply side motor 3
110 to 116,
125, 126,
74: Commercial-power supply side motor 4
145 to 147,
164, 170,
75: Inverter side motor 1 connection RIO1
190, 191,
76: Inverter side motor 2 connection RIO2
194 to 196,
1
9999
77: Inverter side motor 3 connection RIO3
198, 199,
78: Inverter side motor 4 connection RIO4
9999
90, 190: Life alarm
91, 191: Alarm output 3 (power-off signal)
92, 192: Energy saving average value
93, 193: Current average monitor
94, 194: Alarm output 2
95, 195: Maintenance timer alarm
96, 196: Remote output
98, 198: Minor fault output
99, 199: Alarm output
9999:No function
0 to 99: Positive logic, 100 to 199:
Negative logic
Description
undervoltage
detection
(Only for the 01800 or more)
prealarm
output
switchover MC1
switchover MC2
switchover MC3
command is on
occurrence of power failure
(retained until release)
connection RO1
connection RO2
connection RO3
connection RO4
updated timing
All
Param
Param
param
eter
eter
eter
copy
clear
clear
: enabled
× : disabled
×
×
×
×
×
×
×