Parameter
Name
Up-to-frequency
41
sensitivity
Output frequency
42
detection
Output frequency
43
detection for
reverse rotation
Second output
50
frequency detection
44, 45
Refer to Pr. 7 and Pr. 8.
46
Refer to Pr. 0.
47
Refer to Pr. 3.
48, 49
Refer to Pr. 22 and Pr. 23.
50
Refer to Pr. 41 to Pr. 43.
51
Refer to Pr. 9.
DU/PU main display
52
data selection
Watt-hour meter
170
clear
Operation hour
171
meter clear
Monitor decimal
268
digits selection
Energization time
563
carrying-over times
Operating time
564
carrying-over times
Cumulative power
monitor digit shifted
891
times
CA terminal
54
function selection
Frequency
55
monitoring
reference
Current monitoring
56
reference
AM terminal
158
function selection
AM output filter
867
Current output filter
869
Incre
Initial
Range
ments
Value
0.1%
10%
0 to 100% Set the level where the SU signal turns on.
Set the frequency where the FU signal
0.01Hz
6Hz
0 to 400Hz
turns on.
Set the frequency where the FU signal
0 to 400Hz
turns on in reverse rotation.
0.01Hz
9999
9999
Same as Pr.42 setting
Set the frequency where the FU2 signal turns
0.01Hz
30Hz
0 to 400Hz
on.
0, 5, 6, 8 to
Select the monitor to be displayed on the
14, 17, 20, 23
operation panel and parameter unit.
1
0
The setting value of "9" is available only
to 25, 50 to
for the 01800 or more.
57, 100
0
Set "0" to clear the watt-hour meter monitor.
Set the maximum value when monitoring
10
1
9999
from communication to 0 to 9999kWh.
Set the maximum value when monitoring
9999
from communication to 0 to 65535kWh.
Set "0" in the parameter to clear the watt-
1
9999
0, 9999
hour monitor.
Setting "9999" has no effect.
0
Displays the monitor as integral value.
1
9999
1
Displays the monitor in increments of 0.1.
9999
No fixed decimal position
The numbers of cumulative energization
1
0
0 to 65535
time monitor exceeded 65535h is displayed.
Reading only
The numbers of operation time monitor
1
0
0 to 65535
exceeded 65535h is displayed.
Reading only
Set the number of times to shift the
0 to 4
cumulative power monitor digit
Clamp the monitor value at maximum.
1
9999
No shift
9999
Clear the monitor value when it exceeds
the maximum value.
1 to 3, 5, 6, 8
Select the monitor output to terminal CA.
1
1
to 14, 17, 21,
The setting value of "9" is available only
24, 50, 52, 53
for the
Set the full-scale value to output the
0.01Hz
50Hz
0 to 400Hz
output frequency monitor value to terminal
CA and AM.
Rated
Set the full-scale value to output the output
0 to 500/
0.01/
inverter
current monitor value to terminal CA and AM.
0 to 3600A
*9
0.1A
output
*9
*9
current
1 to 3, 5, 6,
Select the monitor output to terminal AM.
8 to 14,
1
1
The setting value of "9" is available only
17, 21, 24,
for the 01800 or more.
50, 52, 53
0.01s
0.01s
0 to 5s
Set the output filter of terminal AM.
0.01s
0.02s
0 to 5s
Adjust response level of current output.
Extended parameters
Description
or more.
01800
The setting depends on the inverter
capacity (01160 or less/01800 or more)
All
Param
Param
param
eter
eter
eter
copy
clear
clear
: enabled
× : disabled
×
×
×
×
×
×
×
×
×
×
×
111