Paradyne 9120 User Manual page 59

Table of Contents

Advertisement

9121-A2-GB20-00
Message
What It Indicates
Invalid Test
A conflicting loopback or
Combination
pattern test was in progress
when Start was selected to
start another test, or was
active on the same or
another interface when
Start was selected.
Limit of six Login IDs
An attempt to enter a new
reached
login ID was made, and the
limit of six login/password
combinations has been
reached.
Limit of 40 Links
A management PVC is
Reached
being created and 40 links
already exist.
Name Must be Unique
Name entered for a
management PVC has
been used previously.
No DLCIs Available for
A management PVC is
Net Link
being created and the
maximum DLCIs already
exist.
No Management PVC
No management PVCs
have been created.
No Security Records
Delete was selected from
to Delete
the Administer Login
screen, and no security
records had been defined.
June 1997
Maintenance and Troubleshooting
What To Do
Wait until other test ends and
message clears.
Cancel all tests from the Test
screen ( Path: main/ test ).
Stop the test from the same
screen the test was started
from.
1. Delete another login/password
combination.
2. Reenter the new login ID.
Do not create the link.
Delete another link, and try
again.
Enter another 4-character name
for the logical/management link.
Do not create the link.
Delete an existing DLCI, and
try again.
Check that the following have
been defined:
IP address
Subnet mask
Frame relay link
DLCIs
EDLCIs, if the DLCI is
multiplexed
No action needed.
Enter a security record.
5-9