Installation
6. Use an ohmmeter (or megohmmeter in the ohm
range) to measure the resistance between the
gun handle (BB) and a true earth ground (CC).
The resistance should not exceed 100 ohms.
7. If the resistance is greater than 100 ohms, check
the tightness of the ground connections and be
sure the air hose ground wire is connected to a
true earth ground. If the resistance is still too
high, replace the air hose.
Figure 22 Check the Electrical Grounding of the
Gun
28
8. Use an ohmmeter (or megohmmeter in the ohm
range) to measure the resistance between the
cabinet ground lug (214) and a true earth ground
(CC). The resistance must be less than 100
ohms.
Figure 23 Check the Grounding of the Cabinet
Flush the
Flush
Flush
the Equipment
the
Equipment Before
Equipment
The equipment was tested in fluid at the factory. To
avoid contaminating your fluid, flush the equipment
with flushing fluid before you use the equipment. See
Flush the System (Systems without Color Change),
page
31.
Before First
Before
First Use
First
Use