A
B
C
KEY
A* Bleed-type Air Shutoff Valve
B
Air Line Filter
C* Pump Air Regulator
D
Air Line Lubricator
E
Pump Runaway Valve
F
Pump
G* Pump Ground Wire
H
Fluid Shutoff Valve
J* Fluid Pressure Regulator
Fig. 1

Fluid Line Accessories

1. Install a fluid filter (S) and drain valve (R) at the
pump outlet. Filtering the fluid will help remove
coarse particles and sediment that could clog the
spray tip.
WARNING
INJECTION HAZARD
The fluid drain valve (R) is required in
your system to assist in relieving fluid
pressure in the displacement pump,
hose and gun; triggering the gun to relieve pres-
sure may not be sufficient. Install a drain valve
close to the pump's fluid outlet. The drain valve
reduces the risk of serious injury, including fluid
injection and splashing in the eyes or on the skin.
Installation
A
D
E
T
K
Pressure Gauge
L* Grounded Fluid Hose
with spring guards
M Gun Fluid Inlet (1/4 npsm)
N
Gun Air Regulator
P
Gun Air Shut-off Valve
Q* Graco Electrically Conductive
Air Supply Hose
(1/4 npsm x 1/4 npsm LH)
(Refer to Fig. 1)
N
F
P
G
Q
J
L
H
K
S
R
R
R* Fluid Drain Valve
S
T
W PRO AA4500 Spray Gun
X
*
2. Install a fluid regulator (J) on the fluid line to con-
trol fluid pressure to the gun.
X
M
WARNING
Fluid Filter
Pump Fluid Inlet
Gun Air Inlet (1/4 npsm LH)
Equipment required for safe operation of
system. Must be purchased separately .
See ACCESSORIES.