Pump Ratio:
Ratio: The ratio of the pneumatic pump for
Pump
Pump
Ratio:
the high pressure supply in air assisted systems. 1:1
must be used for low pressure air spray systems.
Gun
Gun Flush
Gun
Flush
Flush Box:
Box:
Box: Enable if using a gun flush box.
Fill
Fill Start
Fill
Start Delay:
Start
Delay:
Delay: The number of seconds that the
system waits after the gun trigger is released before
it lowers the isolation valve (G) and the system
discharges.
During the course of a spraying operation, the
operator may need to briefly release the gun trigger
before painting another part. Increase the time if you
want the charge to last longer after the gun trigger is
released. (Default: 3 seconds.)
The length of time between when the gun trigger is
released and system discharge is a combination of
66
two settings: the Ground Rod Delay time and the Fill
Start Delay time.
For example, if the Fill Start Delay is set to 7 and the
Ground Rod Delay is set to 5:
1. The gun trigger is released.
2. After 5 seconds the ground rod lowers.
3. In 2 more seconds the isolation valve lowers.
The actual time that the system takes to discharge
depends on these settings, the gun type, and the
hose length.
Ground Rod
Rod Delay:
Delay: The number of seconds that the
Ground
Ground
Rod
Delay:
system waits after the gun trigger is released before
it lowers the ground rod (N), instantly dissipating the
charge.
Color Change:
Change: Select this box to enable color change
Color
Color
Change:
capability.
Colors: Select the number of colors that will be used.
Colors:
Colors:
A system with six color change valves allows 3
colors. A system with 18 color change valves allows
15 colors.
Dump
Dump Enable:
Dump
Enable: Select this box if the dump valve
Enable:
is connected to a hose that empties into a waste
container. If the dump valve is not connected to a
hose, the remaining contents from the isolation fluid
pump will spill out of the system.
Restart System:
System: Select this box to restart the entire
Restart
Restart
System:
system. This is primarily used for initiating a token
software update without manually cycling the power.