Removing And Installing Summit 300-48 Power Supplies - Extreme Networks Summit 200-24 Hardware Installation Manual

Consolidated “e” series
Hide thumbs Also See for Summit 200-24:
Table of Contents

Advertisement

Summit 300 Optional Features
• Internal Power Supply Technical Specifications on page 84

Removing and Installing Summit 300-48 Power Supplies

The Summit 300-48 comes with a minimum of one power supply pre-installed at the factory. Follow the
instructions in this section for removing and installing power supplies. Switches with one power supply
have a metal cover plate in place of the second supply. If you install a second power supply, be sure to
retain the cover plate in case you later decide to use only one supply.
Figure 24: Rear view of a Summit 300-48 showing two power supplies
Removing an Internal Power Supply
To remove an internal Summit 300-48 power supply:
1 Turn off the power supply by setting the power switch to the OFF position.
2 Remove the power cable from the power source, remove the power cable retaining bracket (if
installed), and then remove the power cable from the power supply.
CAUTION
Shock Hazard.
3 Use a #2 Phillips screwdriver to unscrew the two captive retaining screws. See the detail in Figure 24.
4 Grasp the retaining screws, and use them to slowly pull the power supply towards you, as shown in
Figure 25.
WARNING!
Do not insert your fingers or hands into the empty power supply bay.
80