For the 3025 NI with an Automatic Document Feeder (ADF):
Hold the ADF closed when raising the Scanner module to prevent it from opening.
2.
Hold the Scanner to prevent it from falling closed.
Rotate the hinge up and remove the pivot slot
Figure 2 Scanner Support Hinge Removal (Top View)
Xerox® WorkCentre® 3025 Multifunction Printer Service Manual
CAUTION
(Figure
2).
Hinge Pivot
Slot
Removal
Scanner Module Removal
1.
Switch Off the Printer and unplug the Power Cord.
2.
Remove the following covers:
a.
The Front Cover (REP 1.2).
b.
The Right Side Cover (REP 1.1).
3.
Disconnect the Scanner Module and Control Panel connectors (2) from the Main PWB
(Figure
3).
The Figure shows the 3025 BI, the connectors are in the same location for the 3025 NI.
Figure 3 Main PWB Scanner/ Control Panel Connectors
June 2014
4-17
Connectors
Repairs