Viessmann Vitocell 140-E Installation And Service Instructions For Contractors page 33

Solar buffer cylinder
Table of Contents

Advertisement

Vitocell with fitted Solar-Divicon
1.
A
C
B
2.
1. Connect heating water flow connec-
tion pipe A to connection D on the
Vitotrans.
2. Connect heating water return con-
nection pipe B to connection E on
the Vitotrans.
Fitting the lower thermal insulation mat
!
Please note
The thermal insulation must not
come into contact with naked
flames.
Exercise caution when welding
and brazing.
(cont.)
DE F
3.
3. Connect heating water stratification
4. Connect the pipes to the cylinder con-
Note
Only carry out the following steps if the
tightness test (see page 27) was suc-
cessful.
Installation sequence
4.
connection pipe C to connection
F on the Vitotrans.
nections.