Solar buffer cylinder
Table of Contents

Advertisement

Installation sequence
Vitocell with fitted Solar-Divicon
Note
The cover hangs on the heating water
buffer cylinder and is held in position
by the straight capillaries. This is nec-
essary for the rest of the installation.
3. Guide the thermometer sensor capil-
laries to the back of the cylinder and
repeat the steps below for each ther-
mometer sensor.
4. Depending on where the thermome-
ter sensor is to be fitted, position it in
the clamping bracket or pull the sen-
sor retainer out of the sensor well.
5. Secure the sensor to the outside of
the sensor retainer contact spring so
that it is flush with the front of the
spring.
30
(cont.)
6. Secure the thermometer sensor
capillaries.
Note
Never wrap insulating tape around
the thermometer sensor.
7. Insert the sensor retainer as far as it
will go into the sensor well.
8. Fit the retainer with the thermome-
ters.