Advertisement

Quick Links

VIESMANN
Installation and service instructions
for contractors
Vitocell 140-E/160-E
Type SEIC
Type SESB
Solar buffer cylinder
VITOCELL 140-E/160-E
Please keep safe.
5686973 GB
9/2019

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann Vitocell 140-E

  • Page 1 VIESMANN Installation and service instructions for contractors Vitocell 140-E/160-E Type SEIC Type SESB Solar buffer cylinder VITOCELL 140-E/160-E Please keep safe. 5686973 GB 9/2019...
  • Page 2: Target Group

    Safety instructions Safety instructions Please follow these safety instruc- tions closely to prevent accidents and material losses. Safety instructions explained Danger Note This symbol warns against the risk Details identified by the word "Note" of injury. contain additional information. Please note This symbol warns against the risk of material losses and environmen- tal pollution.
  • Page 3: Safety Instructions

    Please note Repairing components that fulfil a safety function can compromise the safe operation of the system. Replace faulty components only with genuine Viessmann spare parts. Auxiliary components, spare and wearing parts Please note Spare and wearing parts that have...
  • Page 4 Index Index Information Disposal of packaging ................Symbols ....................Intended use ..................Product information ................System examples .................. Spare parts lists ..................Preparing for installation Connections ................... Information on siting ................Installing the cylinder with an immersion heater ......... ■ Installation sequence Cylinder without fitted Solar-Divicon ............
  • Page 5: Disposal Of Packaging

    Information Disposal of packaging Please dispose of packaging waste in line with statu- tory regulations. Symbols The steps in connection with commissioning, inspec- Symbol Meaning tion and maintenance are found in the "Commission- Reference to other document containing ing, inspection and maintenance" section and identified further information as follows: Step in a diagram:...
  • Page 6: Product Information

    Incorrect usage also occurs if the components in the system are modified from their intended use (e.g. through direct DHW heating in the collector). Product information Vitocell 140-E, type SEIC and Vitocell 160-E, type ■ With the option to fit a Vitotrans 353 SESB ■...
  • Page 7: Preparing For Installation

    Preparing for installation Connections Front Back View without Solar-Divicon (accessories) Thermometer sensor fixing (below the thermal insu- Heating water flow 1 to the heating circuits/air vent lation) valve Thermometers (up to 4 pce) Heating water flow 2 from the heat generator Heating water flow G 1 Clamping system for the cylinder temperature sen- Return stratification G 1...
  • Page 8 Preparing for installation Information on siting Please note Provide adequate clearance from the wall to allow for ■ The appliance may suffer damage through the operation of the temperature controller (if installed). influence of frost. ■ Placing the heating water buffer cylinder on a plinth Install the heating water buffer cylinder in a will make the room easier to clean.
  • Page 9: Installation Sequence

    Installation sequence Cylinder without fitted Solar-Divicon See page 17 for installation of the version with fitted Solar-Divicon (accessories). Siting and levelling Please note The thermal insulation must not come into con- tact with naked flames. Exercise caution when welding and brazing Fig.
  • Page 10 Installation sequence Cylinder without fitted Solar-Divicon (cont.) Fitting the thermometer sensor (if supplied) and cylinder temperature sensor Fig. 3 1. Guide the thermometer sensor through the cover 6. Tighten the nuts. strip and insert the thermometer. 7. Depending on where the sensor is to be fitted: 2.
  • Page 11 Installation sequence Cylinder without fitted Solar-Divicon (cont.) Fitting the Vitotrans Fig. 4 Fig. 5 1. Fit the bolts to the cylinder. 3. Screw the nuts onto the bolts until hand-tight. 2. Fit the module.
  • Page 12 Installation sequence Cylinder without fitted Solar-Divicon (cont.) DE F Fig. 6 1. Connect heating water flow connection pipe 3. Connect return stratification connection pipe connection on the Vitotrans. connection on the Vitotrans. 2. Connect heating water return connection pipe 4. Secure the pipes to the cylinder connections. to connection on the Vitotrans.
  • Page 13 Installation sequence Cylinder without fitted Solar-Divicon (cont.) Fitting the thermal insulation jacket Please note The thermal insulation must not come into con- tact with naked flames. Exercise caution when welding and brazing Note 2 people are required for the following work. ■...
  • Page 14 Installation sequence Cylinder without fitted Solar-Divicon (cont.) Fitting the cover strips Fig. 8 1. Tighten the nuts on the bolts. 3. Insert the rear sections of the Vitotrans thermal insulation. Observe the groove in the thermal insu- 2. Fit the cover strip. lation.
  • Page 15 Installation sequence Cylinder without fitted Solar-Divicon (cont.) Fig. 9 Shown: Vitocell 100-E, type SEIC, 600 l Type plate 1. Fit the front section of the Vitotrans thermal insula- 3. Fit the rear cover strip to the thermal insulation. tion. 4. Affix type plate 2.
  • Page 16 Installation sequence Cylinder without fitted Solar-Divicon (cont.) Fitting the cover Fig. 10 Viessmann logo Installing the air vent valve on the solar side Fig. 11 1. Push the corrugated hose into the elbow. Continue on page 28. 2. Screw the air vent plug into the elbow.
  • Page 17 Installation sequence Cylinder with fitted Solar-Divicon Siting and levelling Fig. 12 Bag with type plate Bag of 3 adjustable feet 3. Insert the adjustable feet into the supports as far 5. If no immersion heater is installed, seal in the front as they will go, then adjust them to level the cylin- female connection with plug R1 supplied.
  • Page 18 Installation sequence Cylinder with fitted Solar-Divicon (cont.) Fitting the Vitotrans Fig. 13 Fig. 14 1. Fit the bolts to the cylinder. 3. Screw the nuts onto the bolts until finger-tight. 2. Mount the module.
  • Page 19 Installation sequence Cylinder with fitted Solar-Divicon (cont.) DE F Fig. 15 1. Connect heating water flow connection pipe 3. Connect return stratification connection pipe connection on the Vitotrans. connection on the Vitotrans. 2. Connect heating water return connection pipe 4. Connect the pipes to the cylinder connections. to connection on the Vitotrans.
  • Page 20 Installation sequence Cylinder with fitted Solar-Divicon (cont.) Fitting the support panel Fig. 16 Note Use the two lower holes if fitting to the cylinder with 600 l capacity.
  • Page 21 Installation sequence Cylinder with fitted Solar-Divicon (cont.) Making connections on the solar side Fig. 17 1. Remove the bottom pipes. 3. Fit the pipes. 2. Rotate the pipes towards the front until they touch the front adjustable foot.
  • Page 22 Installation sequence Cylinder with fitted Solar-Divicon (cont.) Fig. 18 1. Push the corrugated hose into the elbow. 5. Fit the solar return pipe. 2. Screw the air vent plug into the elbow. 6. Before the Divicon is fitted: Attach thermal insula- tion to the pipes –...
  • Page 23 Installation sequence Cylinder with fitted Solar-Divicon (cont.) Installing the Solar-Divicon Solar-Divicon installation instructions Please note Cables can be damaged if exposed to hot com- ponents. Ensure adequate thermal insulation between cables and hot pipework. Fig. 19 Connecting the Solar-Divicon on the solar side and checking for leaks Please note Note Once the thermal insulation and thermal insula-...
  • Page 24 Installation sequence Cylinder with fitted Solar-Divicon (cont.) Fitting the thermal insulation cover Fig. 20...
  • Page 25 Installation sequence Cylinder with fitted Solar-Divicon (cont.) Fitting the thermometer sensor (if supplied) and cylinder temperature sensor Fig. 21 1. Guide the thermometer sensor through the retainer 6. Tighten the nuts. and insert the thermometer. 7. Depending on where the sensor is to be fitted: 2.
  • Page 26 Installation sequence Cylinder with fitted Solar-Divicon (cont.) Fitting the thermal insulation jacket Please note Note The thermal insulation must not come into con- 2 people are required for the following work. ■ tact with naked flames. ■ Ensure that no fleece remnants enter the cylinder Exercise caution when welding and brazing through the cylinder connections.
  • Page 27 Installation sequence Cylinder with fitted Solar-Divicon (cont.) Fitting the cover strips Fig. 23 Shown: Vitocell 100-E, type SEIC, 600 l Type plate 1. Tighten the nuts on the bolts. 4. Fit the rear cover strip to the thermal insulation. 2. Fit the front section of the Vitotrans thermal insula- 5.
  • Page 28: Connections On The Heating Water Side

    Installation sequence Cylinder with fitted Solar-Divicon (cont.) Fitting the cover Fig. 24 Connections on the heating water side ■ Adjust the temperature controller and the high limit Note safety cut-out so that the heating water temperature For connection locations, see page 7. in the heating water buffer cylinder does not exceed 110 °C.
  • Page 29: Connecting The Equipotential Bonding

    Installation sequence Connecting the equipotential bonding Connect the equipotential bonding in accordance with CH: Connect the equipotential bonding in accordance the requirements stipulated by your local power supply with the technical requirements stipulated by your local utility and VDE [or local] regulations. power supply utility and SEV regulations.
  • Page 30 Commissioning, inspection, maintenance Ventilation on the solar side Fig. 25 1. Open the clip fasteners and pull them apart. Note If white creases appear on the surface of the thermal 2. Slightly pull the thermal insulation to the side. Vent insulation, these can be removed with hot air (e.g.
  • Page 31: Commissioning/Service Reports

    Commissioning/service reports Commissioning/service reports Commissioning Maintenance/service Maintenance/service Date: Maintenance/service Maintenance/service Maintenance/service Date: Maintenance/service Maintenance/service Maintenance/service Date: Maintenance/service Maintenance/service Maintenance/service Date: Maintenance/service Maintenance/service Maintenance/service Date:...
  • Page 32 Specification Specification Vitocell 140-E Vitocell 160-E Cylinder capacity DIN registration no. 9W264E 9W265E Standby heat loss kWh/24 h 2.10 2.25 2.45 2.25 2.45 To EN 12897:2016 with 45 K temperature differential Dimensions Length ( Incl. thermal insulation 1064 1064 1064...
  • Page 33: Specification

    Specification Specification (cont.) Immersion heater Rated output in standard mode Rated voltage 3/N/PE 400 V/50 Hz Rated current 17.4 17.4 17.4 Type SEIC (600 l) Heat-up time from 10 to 60 °C ■ Capacity that can be heated by the im- ■...
  • Page 34 Disposal Final decommissioning and disposal Viessmann products can be recycled. Components For decommissioning the system, isolate the system and substances from the system are not part of ordi- from the power supply and allow components to cool nary household waste.
  • Page 35: Declaration Of Conformity

    Certificates Declaration of conformity We, Viessmann Werke GmbH & Co. KG, D-35107 Allendorf, declare as sole responsible body that the named product complies with the European directives and supplementary national requirements in terms of its design and operational characteristics. Using the serial number, the full Declaration of Con- formity can be found on the following website: www.viessmann.co.uk/eu-conformity...
  • Page 36 Heating water side connections......... 28 Thermometer sensor..........10, 25 Immersion heater........... 8, 33 Vitotrans, fitting.............11, 18 Intended use..............5 Product information............6 Viessmann Werke GmbH & Co. KG Viessmann Limited D-35107 Allendorf Hortonwood 30, Telford Telephone: +49 6452 70-0 Shropshire, TF1 7YP, GB...