AUXILIARY POWER RECEPTACLES:

Combined continuous output of all receptacles is limited to 9.5kW
for the Ranger 260MPX and 10.0kW for the Ranger 330MPX. The
current rating of any plug used with a receptacle must be at least
equal to the rating of the receptacle.
Output voltage is within ±5% at all loads up to rated capacity.
FIGURE B.2
3
2
4
1
5
TABLE B.6
1 GFCI
The GFCI module protects the (2) 120 VAC
module
duplex receptacles. A red light illuminates when
power is applied to the 120 VAC duplexes.
2 50 amp
circuit
breaker
3 20 amp
Protects the GFCI and (2) 120 VAC duplexes
circuit
from overload. If the circuit breaker opens, the
breaker
receptacles will not work. Press to reset. If it
continues to remain open, contact an authorized
Lincoln service shop.
4 120 VAC
The 120 VAC duplex receptacles should only be
duplex
used with three wire grounded type plugs or
approved double insulated tools with two wire
plugs.
5 120/240
VAC 14-
50R
recept.
6 240 VAC
6-50R
recept.
7 Neutral
If the machine is to be grounded, use a AWG #8
Stud
copper wire or larger to a solid earth ground.
Refer to local codes and the U.S. National
Electrical Code.
6
7
4
B-14