Programming -Machine Calibration - Newco Bistro 10 T3 Operating Instructions Manual

Table of Contents

Advertisement

3. Select
"Calibration"
"LH Mix Bowl Cal", Insert a measuring container capable of holding 32 or more ounces
of water under delivery area of machine, then press the top left button to start calibration
countdown period of 30 seconds. (Note: if machine is not up to temperature, machine will
wait until temperature is reached before running calibration cycle, display will read
"Preparing to Brew") At the end of the calibration cycle, display will change to "Adjust LH
Mix bowl Cal"
Enter the value measured (Step 5, above right) and press the Upper Right button when
done- screen will change to "LH Mix Bowl Cal" again. This is in case there was a spill or
problem during the cycle and the measurement needs to be repeated- - to repeat press
Dump
the top right button to restart cycle.
Valves
"RH Mix Bowl Cal", Insert a measuring container capable of holding 32 or more ounces
of water under delivery area of machine, then press the top left button to start calibration
countdown period of 30 seconds. (Note: if machine is not up to temperature, machine will
wait until temperature is reached before running calibration cycle, display will read
"Preparing to Brew") At the end of the calibration cycle, display will change to "Adjust
RH Mix bowl Cal"
Enter the value measured (Step 5, above right) and press the Upper Right button when
done- screen will change to "RH Mix Bowl Cal" again. This is in case there was a spill or
problem during the cycle and the measurement needs to be repeated- - to repeat press
the top right button to restart cycle.

Programming -Machine Calibration

Calibration
1. Press Button to Select "Calibration"
2. Toggle Selection to "Calibration"
4. Press Button to Toggle display
Mix Bowl Calibration Value (Ounces)
Left Auger Speed 0-10
Left Auger Calibration Value in grams
Center Auger Speed 0-10
Center Auger Calibration Value in grams
Right Auger Speed 0-10
Right Auger Calibration Value in grams
Coffee Calibration Value (Ounces)
Exit Calibration
Change Values
UP or DOWN
18
Factory Defaults
Left Mix Bowl Cal
Right Mix Bowl Cal
Left Auger Speed
Left Auger Cal
Ctr Auger Speed
Ctr Auger Cal
Right Auger Speed
Right Auger Cal
Coffee Cal
5. Use to
Value
20.0
20.0
9
156
9
156
9
90
23