Additional Functions - Ariston ABS VLS EVO INOX PW 80 Instructions For Installation, Use, Maintenance

Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 49
Error reset: reset the appliance by switching it off and on from the ON/OFF button (Ref. A). If the cause of the
malfunction disappears immediately when reset, the appliance resumes its regular operation. On the contrary, if
the error code continues to appear on the display: contact the Technical Service Centre.

Additional Functions

Remaining time
For models equipped with user interface type shown in figure 10:
The time remaining to reach the temperature set by the user is shown in the centre of the display (Ref. F).
The value is indicative and it is an estimation of the "time remaining" parameter. The value is automatically upda-
ted during the heating phase.
Anti-freeze function
The anti-freeze function is the appliances automatic protection to avoid damages caused by very low temperatu-
res below 5 °C, in the event in which the product is turned off during winter. It is recommended that the product
remains plugged in to the mains power, even if it is inactive for a long time.
• For models equipped with user interface type shown in figure 9 and 11: the function is enabled, but not
recommended if activated.
• For models equipped with a user interface type shown in figure 10: the function is enabled; activation is
displayed on the display with "AF".
For all models, once the temperature rises to a safer level such as to avoid damage from ice and frost, the water
heating is switched off again.
Wi-Fi Heating Mode
• For models equipped with a user interface type shown in figure 11:
A smart remote control and programming of the heating mode is possible using the specific app (App name can
be found in the quick start guide). The app is free and available on Google play and App Store. Please refer to
"Wi-Fi Function" paragraph.
Weekly program function
• For models equipped with a user interface type shown in figure 11:
The weekly program function can be activated only via App. There is no feedback on the HMI that this mode has
been selected.
The user can select for each day of the week two different set point temperatures at two different times: the pro-
duct will calculate the heating rise velocity and depending on it the best time to start heating in order to satisfy
setpoint at the desired time.
If [PLUS] or [MINUS] buttons are pressed the function will be deactivated.
If ECO function is selected WEEKLY PROGRAM will be deactivated.
User Advanced Menu
• For models equipped with user interface type shown in figure 10:
When the product is switched on, touch of the "Mode" button for 3 seconds, the advanced user menu is opened,
"U01" appears. By rotating the knob, the desired function can be selected. Press "set" button and then rotate the
knob in order to change the value of the function. Set "01" (to activate the function) or "00" (to disable the fun-
ction) using the knob. When the new value is chosen, press "set" button in order to come back to the advanced
menu. Press "Mode" button to exit from advanced menu. The new setting is active.
This advanced user menu contains following functions:
Parameter
Identifier
U1
Thermal disinfection function (see "Thermal disinfec-
tion function" paragraph)
U2
Limescale function
U3
Buzzer
U4
Maximum Temperature setting (maximum tempera-
ture that can be set in manual mode)
Activating the "thermal disinfection cycle" (anti-legionella)
The anti-legionella function (enabled by default) consists of a water heating cycle at 65 °C which carries out a
thermal disinfection action against the bacteria in question.
If enabled, the appliance performs a heating cycle at 60 °C for 1 hour, every day. When the product is off, the
anti-legionella function is not active. If the appliance is switched off during the anti-legionella cycle, the product
turns off and the function is not completed. If the product is turned on again, the anti-legionella function is
reactivated. At the end of each cycle, the operating temperature returns to the value set previously by the user.
Description
LABEL
Default
«bact»
01 (ON)
«CALC»
00 (OFF)
«bEEP»
01 (ON)
«tSAF»
80°C
EN
Range
00/01
00/01
00/01
40-80°C
59