11. The electrical hookup must be done as indicated in this manual.
12. If the appliance is equipped with a power cord, the latter may
only be replaced by an authorised service centre or professional
technician.
13. Do not tamper with the overpressure safety device, if supplied to-
gether with the appliance; trip it from time to time to ensure that
it is not jammed and to remove any scale deposits. In countries
which have enacted EN 1487, the appliance's intake pipe must be
equipped with a safety device compliant with the said standard,
calibrated to a maximum pressure of 0.7 MPa, including at least a
cock, check valve, safety valve and hydraulic load cutout.
14. It is normal that water drip from the overpressure safety device
and EN 1487 safety unit when the appliance is heating. For this
reason one must install a drain, open to the air, with a continu-
ously downwards sloping pipe, in an area not subject to subzero
temperatures. Make sure to drain the appliance when it is out of
service or in an area subject to subzero temperatures.
15. Make sure to drain the appliance when it is out of service or in an
area subject to subzero temperatures.
16. Water heated to over 50° C can cause immediate serious burns if
delivered directly to the taps. Children, disabled persons and the
aged are particularly at risk. We recommend installing a thermo-
static mixer valve on the water delivery line, marked with a red
collar.
17. Do not leave flammable materials in contact with or in the vicini-
ty of the appliance.