Ariston ABS VLS EVO INOX PW 80 Instructions For Installation, Use, Maintenance page 57

Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 49
EN
Setting- changing local time.
To change local time, when the machine is first switched on, the product automatically prompts you to set the
correct time; during subsequent use the "set" button must be held down for 3 seconds. To change current time,
turn the knob and press the "set" button to confirm. Repeat the operation to set minutes.
Programming mode (Manual, Program 1, Program 2, Program 1 and 2).
On each touch of the "Mode" button a different operating mode is selected (indicated by the corresponding
flashing writing: P1, P2, Man). The selection of the functions is cyclical and follows this order: P1, P2, P1 and P2
together, manual, P1 new, etc. The programs "P1" and "P2" are set by default for the time bands 07:00 and 19:00
and at a temperature of 70 °C.
"Manual" mode (symbol "Man" on).
Allows the user to set the desired temperature simply by turning the knob until the desired temperature is
displayed (Ref. E) (the adjustment range is 40 °C - 80 °C) and in the display you can see the number of showers
available based on the related on icons . By clicking the set button, the setting is saved. Both during the tem-
perature selection phase and in the heating phase you can display the waiting time (Ref. F) that the product will
take to reach the target set.
The "Program 1" (writing "P1" on), "Program 2" (writing "P2" on) and "Program 1 and 2" (writing "P1" and "P2" on)
allow you to program up to two time bands of the day when you want to have hot water. Press the "mode" button
until the writing related to the desired program starts flashing. Now set the time at which hot water is desired
by turning the knob (select the time by 30 minutes increments). By pressing the "set" button, the time is saved.
To set the water temperature to the desired level, turn the knob and press the "set" button to save the setting.
Press the "set" button to start appliance operation in "P1" or "P2" mode. If "P1 and P2" have been selected repeat
the time and temperature setting for the second program. During the periods for which the use of hot water
is not explicitly required, water heating is disabled. The individual programs "P1" or "P2" are equivalent and can
be configured independently for greater flexibility. When one of the programming functions ("P1" or "P2" or "P1
and P2") is enabled, the knob is disabled. If you want to change the parameters, you must press the "set" button.
If one of the programming functions ("P1" or "P2" or "P1 and P2") is used in combination with the "ECO" function
(see paragraph "ECO EVO function"), the temperature is set automatically by the appliance and only the desired
time bands for hot water availability can be set
NB: for any setting, if the user takes no action for 5 seconds, the system saves the last setting.
ECO EVO Function
The "ECO EVO" function is a software program that automatically "learns" user consumption levels, reducing
heat loss to a minimum and maximising energy savings. The "ECO EVO'' software consists of an initial saving
period of a week, when the product begins to operate at the temperature set. At the end of this "learning" week,
the software adjusts water heating according to the user's real needs which are automatically identified by the
appliance. The product guarantees a minimum reserve of hot water even during periods in which water is not
withdrawn.
The hot water demand learning process, continues even after the first week. The process achieves maximum
efficiency after four weeks of learning.
Whenever the "ECO EVO" function or the product is turned off and on again, the function will continue to learn
the levels of consumption. In order to guarantee proper operation of the program, it is recommended not to
disconnect the appliance from the mains. An internal memory ensures data storage for up to four hours without
electricity, after which all acquired data is cancelled and the learning process will begin from the start.
Each timewhen you change the temperature, the "ECO EVO" function is automatically disabled and the
relative writing turns off. The product continues to operate with the program selected, the ECO function is not
active.
• For models equipped with user interface type shown in figure 9 and 10:
Activate the function by pressing the corresponding button, which will light up. In this mode, the manual
selection of the temperature is possible, however changing it disables the "ECO EVO" function.
Reactivate it by pressing the "ECO" button.
To voluntarily cancel the acquired data, hold down the "ECO" button for more than 5 seconds. When the reset
process is completed, "ECO" flashes quickly to confirm data cancellation.
• For models equipped with user interface type shown in figure 11:
Activate the function by pressing "+" and "-" buttons to be pressed shortly; 50°C LED flash for 5 s to indicated the
activation, 70°C flash for 5s to indicate deactivation. In this mode, the manual selection of the temperature is
possible, however changing it disables the "ECO EVO" function.
Reactivate it by pressing "+" and "-" buttons.
To voluntarily cancel the acquired data, hold down the "+" and "+" buttons for more than 5 seconds. When the
reset process is completed, the 50°C/70°C LEDs flash for 5 second to confirm data cancellation.
57

Advertisement

Table of Contents
loading

Table of Contents