Installation sequence
500 l capacity
(cont.)

Fitting the thermal insulation jacket

Note
Ensure that no fleece remnants enter the DHW cylin-
der through the cylinder connections.
2 people are required for the following work.
6x
2.
6x
4.
6x
Fig. 11
1. At the back of the cylinder: Attach 6 clip fasteners
to the edges of the right and left sections of the
thermal insulation jacket. Place the thermal insula-
tion jacket around the cylinder body.
Note
Leave the clip fasteners in the first notch.
2. At the front of the cylinder: Attach 6 clip fasteners
to the edges of the right and left sections of the
thermal insulation jacket.
14
6x
1.
3.
3. Push the clip fasteners at the back of the cylinder
as close together as possible.
4. Push the clip fasteners at the front of the cylinder
as close together as possible.