500 l capacity
(cont.)
Fitting the thermometer sensor (if supplied) and cylinder temperature sensor
1.
Fig. 10
1. Guide the thermometer sensor through the cover
strip. Insert the thermometer.
Note
The cover strip is held in its vertical position by the
straight capillaries. This is necessary for the rest of
the installation.
2. Insert the upper thermometer sensor as far as it
will go into the hole in the cylinder cap.
3. Use clips to secure the thermometer sensor
against being pulled out.
4. Route the bottom thermometer sensor capillaries
to the back of the cylinder body.
5. Screw the nuts onto the threaded studs. Do not
tighten.
3.
2.
4.
6. Slot the clamping devices onto the threaded studs
7. Tighten the nuts.
8. Depending on where the sensor is being fitted:
6.
A
and align.
Insert the thermometer sensors and cylinder
temperature sensor into clamp
will go.
Note
Never wrap insulating tape around the sensors.
■
When the thermal insulation is being fitted, the
■
cylinder temperature sensor leads are routed
outwards through the apertures (slots) in the rear
cover strip.
Installation sequence
5.
7.
8.
A
as far as they
13