Fitting The Thermal Insulation Jacket - Viessmann Vitocell 140-E Installation And Service Instructions For Contractors

Solar buffer cylinder
Table of Contents

Advertisement

Installation sequence
Vitocell without fitted Solar-Divicon

Fitting the thermal insulation jacket

!
Please note
The thermal insulation must not come into con-
tact with naked flames.
Exercise caution when welding and brazing.
Note
2 people are required for the following work.
Ensure that no fleece remnants enter the heating
water buffer cylinder through the cylinder connec-
tions.
2.
Fig.7
1. At the back of the cylinder: Attach 6 clip fasteners
to the edges of the right and left sections of the
thermal insulation jacket. Place the thermal insula-
tion jacket around the cylinder body.
Note
Leave the clip fasteners in the first notch.
2. Fit 4 clip fasteners above and 2 clip fasteners
behind the Vitotrans so that they are evenly
spaced.
12
(cont.)
1.
3.
4.
3. Push the clip fasteners as close together as possi-
4. Install the immersion heater EHE or seal the hole
ble.
with a cover.