Repair Procedures - Daikin FTXA20A Service Manual

Split stylish r32
Table of Contents

Advertisement

2
|
Components

2.4.2 Repair procedures

To remove the front panel motor
Service manual
66
Pins
1-2
1-3
1-4
1-5
2-3
2-4
2-5
3-4
3-5
4-5
Front panel motor resistance
measurements are correct?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the 2 screws and remove the front panel motor from the indoor unit.
a Screw
b Front panel motor
2 Disconnect the harness from the front panel motor.
3 To install the front panel motor, see
Measured resistance (Ω)
232.5~267.5
465~535
Action
Return to the troubleshooting of the
specific error and continue with the
next procedure.
Replace the front panel motor, see
"2.4.2 Repair
b
a
a
"2.4.2 Repair
FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
4
procedures" [
 66].
"2.14 Plate
work" [
4
 120].
4
procedures" [
 66].
RXA20~35A(9) + RXA42+50B
Split Stylish R32
ESIE18-03D – 2021.05

Hide quick links:

Advertisement

Table of Contents
loading