Wifi Control Pcb; Checking Procedures - Daikin FTXA20A Service Manual

Split stylish r32
Table of Contents

Advertisement

2.20 Wifi control PCB

2.20.1 Checking procedures

To perform a power check of the wifi control PCB
FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
RXA20~35A(9) + RXA42+50B
Split Stylish R32
ESIE18-03D – 2021.05
1 As there is no specific check procedure for this component, first perform a
check of the indoor unit main PCB to check if the wifi control PCB needs to be
replaced. See
"2.8.1 Checking
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
1 Remove the required plate work, see
2 Turn ON the power of the unit.
3 Measure the power supply voltage between the pins 4‑5 on the wifi control
PCB connector.
Result: The measured voltage MUST be 10~16 V DC.
a Wifi control PCB assembly
Is the measured power supply voltage
correct?
Yes
No
4 Measure the output voltage between between the pins 4‑5 on the connector
S801 on the indoor unit main PCB.
Result: The measured voltage MUST be 10~16 V DC.
Is the output voltage on the indoor unit
main PCB correct?
Yes
No
5 As there are no further check procedures for this component, perform a check
of the indoor unit main PCB to check if the wifi control PCB needs to be
replaced. See
"2.8.1 Checking
4
procedures" [
 75].
"2.14 Plate
work" [
a
Action
Skip the next step..
Continue with the next step.
Action
Replace the wifi control PCB wiring
harness, see
"2.20.2 Repair
4
procedures" [
 154].
Perform a check of the indoor unit main
PCB, see
"2.8.1 Checking
4
procedures" [
 75].
4
procedures" [
 75].
2
Components
|
4
 120].
Service manual
153

Hide quick links:

Advertisement

Table of Contents
loading