Daikin 4MXS-R Series Service Manual page 278

Multi-split type air conditioners
Table of Contents

Advertisement

Wiring Diagrams
3MXS24RMVJU, 3MXS24RMVJUA
GRN/YLW
POWER SUPPLY
X1M
BRN
L1
L1
BLU
L2
L2
TO INDOOR UNIT
X2M
ROOM B
1
1
2
2
3
3
TO INDOOR UNIT
X3M
ROOM A
1
1
2
2
3
3
TO INDOOR UNIT
X4M
ROOM C
1
1
2
2
3
3
RED
YLW
BLU
Z4C
SHEET
METAL
INDOOR
OUTDOOR
C110
: CAPACITOR
DB1
: DIODE BRIDGE
FU1, FU2, FU3
: FUSE
IPM1
: INTELLIGENT POWER MODULE
L1, L2
: LIVE
FIELD WIRING
LED1~LED5, LEDA
: PILOT LAMP
M1C
: COMPRESSOR MOTOR
M1F
: FAN MOTOR
Note:
PCB1: Main PCB
PCB2: Service monitor PCB
Refer to Part 3 for Printed Circuit Board Connector Wiring Diagram.
265
WIRING DIAGRAM
PCB2
LED
A
1
2
3
4
Z1C
S501
1
Z2C
Z5C
PCB1
E1
E2
1
S201
SA1
FU3
V2
30A
HL1
MRM10
ZF
V3
HN1
FU1
3.15A
1
S
WHT
RED
BLU
ROOM A
ROOM B
ROOM C
9
1
S20
5
1
S21
5 1
S22
5
M
M
M
Y1E
Y2E
Y3E
MR4, MRM10, MRM20
: MAGNETIC RELAY
PCB1, 2
: PRINTED CIRCUIT BOARD
PS
: SWITCHING POWER SUPPLY
Q1L
: OVERLOAD PROTECTOR
R1T~R6T, R9T~R11T
: THERMISTOR
S, S2~S502, X11A
: CONNECTOR
SA1
: SURGE ARRESTER
SHEET METAL
: TERMINAL BLOCK FIXED PLATE
SW2
SW4
SW6
5
SW1
SW3
SW5
S2
S502
11
1
5
11
1 S202
5
MRM20
DB1
~
V401
PS
~
S92
1
10 1
R9T
R10T
R11T
<GAS PIPE>
SW1
: FORCED OPERATION ON/OFF SW (SW1)
SW2
: FORCED OPERATION MODE SELECT SW (SW2)
SW3
: WIRING ERROR CHECK SW (SW3)
SW4
: PRIORITY ROOM SETTING SW (SW4)
SW5
: FUNCTION SW (SW5)
SW6
: NIGHT QUIET MODE SETTING SW (SW6)
V2, V3, V401
: VARISTOR
X1M~X4M
: TERMINAL BLOCK
M1F
Y1S
1
3
7
S80
MR4
FU2
3.15A
DC+
+
+
C110
-
DC-
S93
S90
S40
11
1
8
1
4
R4T
R5T
R6T
R3T
R2T
R1T
Q1L
<LIQUID PIPE>
Y1E~Y3E
: ELECTRONIC EXPANSION VALVE COIL
Y1S
: REVERSING SOLENOID VALVE COIL
Z1C~Z5C
: FERRITE CORE
ZF
: NOISE FILTER
: PROTECTIVE GROUND
: GROUND
SiUS121736EA
M1C
MS
~
3
MS
X11A
Z3C
4
3
2
1
W V
U
S70
W V U
+
-
IPM1
C: 3D100696A
Appendix

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents