3. Other Alarm Visual and Audible Indicators

Operational Mode
normal (standby)
test (button press when
no alarm condition is
present)
Smoke Alarm Memory
(unit has experienced
a smoke alarm event
within the last hour)
Smoke Alarm Hush
Mode, (SMArt HUSH®
control)
locate
Smoke Alarm Hush
Mode canceled
Initiating Alarm,
(Multiple alarms in an
interconnected system)
6
Visual Indications
AC power: Green LED on continu-
ously during light conditions, or blink
every 60 sec during dark conditions.
DC power: Green LED blink approx
every 60 sec.
4 patterns of Red/Amber/Green.
Test: Red LED blinks in time with
alarm pattern. Safety light will briefly
illuminate on model P4010LACS-W.
Green LED fade on/off at
test complete.
Red and Amber LED alternate on 1
sec, every 10 sec.
Red LED blinks every 2 sec.
None
None
Green LED blinks once per sec indi-
cating that this is the unit initiating
the alarm in an interconnected,
multiple alarm, system.
Audible Indications
Button press sound
Voice: "Testing, this is very loud.
Press now to cancel test. 5, 4, 3, 2, 1."
3 long beeps, Voice "Fire!", 3 long
beeps, Voice "Test Complete," Power
on/reset sound.
Voice "Test Canceled" if button
pushed before test sequence begins.
After button push: "Smoke previously
detected," only on the initiating
alarm unit.
After button push: "Hush Mode
Activated."
Smoke alarm pattern stops.
(If there is too much smoke to allow
Hush: Voice "Too Much Smoke, Alarm
cannot be Hushed" Smoke alarm
pattern continues.)
After button push on non-initiating
unit, only initiating unit continues
alarm pattern.
Voice message "Hush Mode
Canceled."
Unit in Smoke Alarm mode.
Action/Note:
Perform Test/Hush button
press once a week to verify
proper alarm operation
* Push/release button before
the countdown ends to
cancel test.
Push test button to clear
Alarm Memory. NOTE: stan-
dard test sequence will follow.
(Push/release button again to
cancel test).
This feature is to be used
only when a known alarm
condition, such as smoke from
cooking, activates the alarm.
Use this to quickly locate the
alarm source and determine if
alarm is nuisance or real.
When smoke levels drop
below the alarm threshold,
the voice message "Hush
Mode Canceled" will occur .
During alarm, the initiating
alarm red blink will be inter-
rupted by a green blink.

Hide quick links: