note:
AC power should be turned off at this stage.
After selecting the proper location for your Alarm, and wiring the AC
QUICK CONNECT harness as described in the WIRING INSTRUCTIONS,
attach the mounting bracket to the electrical box. To ensure aesthetic
alignment of the alarm with the hallway, or wall, the "A" line on the
mounting bracket must be parallel with the hallway when ceiling
mounted, or horizontal when wall mounted.
Pull the AC QUICK CONNECTOR through the center hole in the mount-
ing bracket and secure the bracket, making sure that the mounting
screws are positioned in the small ends of the keyholes before tighten-
ing the screws.
If you are installing for wireless interconnect function, and have not yet setup your wireless alarm network, do
not connect your wireless unit to the AC quick connect harness or mounting bracket yet. Go back to Section 9:
ACTIVATION AND WIRELESS ALARM NETWORK. If you are not using the wireless interconnect function, or if you have
finished wireless alarm setup, then proceed with the following three steps.
Plug the AC QUICK CONNECTOR into the wiring harness attached to the unit, making sure that the locks on the
connector snap into place. Then push the excess wire back into the electrical box through the hole in the center of
the mounting bracket.
Install the alarm fully on the mounting bracket by rotating the alarm in a clockwise direction.
mount to the bracket in 4 positions (every 90 degrees).
automatically activate the battery backup.
Turn on the AC power. The green AC Power On Indicator should be lit when the alarm is operating from AC power.
AC connector
shipped with
product
AC connector
note:
Installing the alarm on the mounting bracket will
Figure 10-B
Existing Kidde
AC Connector
(either connector
can be used for
this model)
note:
The alarm will
19