Firmware Upgrades
Firmware for the RGB-DVI 300, RGB-HDMI 300, or RGB-HDMI 300 A can be upgraded using
the Extron Firmware Loader utility by following the steps below:
1.
2.
3.
4.
5.
Power on the scaler and a computer with internet access.
Connect the computer to the video scaler through either the front panel Config port or
the rear panel RS-232 captive screw connectors.
If necessary, install the Extron Firmware Loader utility. This is on the software disk that
ships with unit or can be downloaded, free of charge, from the Extron web site
(www.extron.com).
From the same site, download the firmware for the scaler.
To download either the Firmware Loader or the firmware for the scaler, click on the
Download tab on the Extron home page:
Figure 23.
Extron Download Center Web Page
Make a note of the folder in which the firmware file is saved.
The file name is in the format RGB_XXX_300_v1.01.BIN.
NOTE: The same firmware can be used with the RGB-DVI 300, RGB-HDMI 300, or
RGB-HDMI 300 A.
Open the Extron Firmware Loader by clicking on the desktop icon.
The Connection dialog box opens:
Figure 24.
Connection Dialog Box
RGB-DVI 300 and RGB-HDMI 300 (A) • Software and Firmware
25