[IR out]
Sets the terminal used for the IR signal output.
[IR OUT]: IR output terminal
[DIGITAL LINK]: DIGITAL LINK OUT terminal
[Serial control]
Sets the terminal used for the serial communication
input.
[SERIAL IN]: Serial terminal
[DIGITAL LINK]: DIGITAL LINK IN terminal
[Serial out]
Sets the terminal used for the serial communication
output.
[SERIAL OUT]: Serial output terminal
[DIGITAL LINK]: DIGITAL LINK OUT terminal
[Display ID]
Set ID number when controlling the Display with
[Controller ID function] and [Serial ID function].
0 to 100 (Standard value: 0)
[Controller ID function]
Enables/disables the [Controller ID function].
[Off]:
Disables the [Controller ID function]. (Can be
operated as normal remote control.)
[On]:
Enables the [Controller ID function]. Effective on
switching to [On].
Note
To use the [Controller ID function], setting ID numbers
both for the remote control and for the display unit is
required.
For ID number setting for the remote control, see
page 111.
About how to reset the settings to defaults:
"Initialization" (see page 80)
[Serial ID function]
Set to control external control with the PC connected to
SERIAL terminal according to the Display's ID number.
[Off]:
Disables external control by the ID.
[On]:
Enables the external control by the ID.
54
English
[Serial response (Normal)]
Sets whether to send the response command to normal
commands without ID.
[Off]:
Does not respond. (Including the inquiry command)
[On]:
Responds.
[Serial response(ID all)]
Set whether to respond to the command or not, when
serial command of ID number "0" is received.
[Off]:
Does not respond.
[On]:
Responds.
[Serial ID group]
When controlling multiple displays simultaneously via
serial communication, those displays are grouped as
one.
A to G (7 groups)
[Serial response(ID group)]
Sets whether to respond to the command or not,
when serial command, which the group is specified, is
received.
[Off]:
Does not respond.
[On]:
Responds.
[Serial daisy chain position]
Sets the first and the last terminals of the daisy chain
connection when serial-controlling this unit by the
daisy chain connection (including connection via the
SERIAL IN/OUT terminal or via DIGITAL LINK, or mixed
connection).
[---]:
When controlling this unit alone with serial control, or
connecting at a position other than the first and last
terminals in a daisy chain
[Top]:
When connecting at the first terminal in a daisy chain
[End]:
When connecting at the last terminal in a daisy chain