Issue an SDO write command to activate the transmission of analog input data from the MELSEC_STlite node
ReleaseAnalogInputdata
StartSDOWrite
MELSEC_STliteHeartbeatActive
MELSEC_STlitePreoperational
29
Execute an SDO write command to the index 6423, sub-index 0 of node address 3
WriteNodeAddress
WriteDataLength
StartSDOWrite
30
If a SDO write command execution is completed, reset its execution signal
SDOWriteCompleted
31
If a SDO write command execution error occurs, increase the command error counter
SDOWriteError
32
If a SDO write command execution is completed, increase the command complete counter and move to the next command
SDOWriteCompleted
SDOWriteError
AND
H6423
SDOWriteCommand
SDOWrite
0
HeadAddress
NodeAddress
WriteIndex
Index
WriteSubIndex
SubIndex
WriteDataLength
WriteData[0]
WriteData
WriteCommand
RST
EN
ENO
d
INCP
EN
ENO
d
AND
MOV
EN
ENO
K3
s
d
WriteNodeAddress
MOV
EN
ENO
s
d
WriteIndex
MOV
EN
ENO
H0
s
d
WriteSubIndex
MOV
EN
ENO
K1
s
d
WriteDataLength
MOV
EN
ENO
K1
s
d
WriteData[0]
SET
EN
ENO
d
StartSDOWrite
RST
EN
ENO
d
ReleaseAnalogInputdata
WriteCompleted
SDOWriteCompleted
WriteError
SDOWriteError
WriteErrorCode
SDOWriteErrorCode
StartSDOWrite
SDOWriteErrorCounter
INCP
EN
ENO
d
SDOWriteOkCounter
SET
EN
ENO
d
PDOSetupProcessing
MOV
EN
ENO
K1
s
d
CommandSequence
13 Program Example