Note
Connection information
The power cable must comply with the valid regulations and conditions for the place of
installation and be provided with a protective conductor at the potential of the enclosure. The
cross-section of each wire must be ≥ 1 mm
• Connect the phase conductor, neutral conductor (N) and the protective conductor (PE) to
the designated position in the plug.
• Make sure that a power disconnection device is located in the direct vicinity of the device
(for load rating, see nameplate).
• Make sure that the supply voltage matches the voltage specified on the nameplate of the
device.
Procedure
Figure 5-1
1. Connect the wires of the connecting cable to the appliance plug
power supply and PE conductor connections are correct!
If you are using the power plug that is available as an option, tighten the screws in the
appliance plug with the following torques:
– 0.5 Nm at the terminals
– 0.3 Nm at the cable terminals (strain relief) and the connector enclosure
2. Connect the appliance plug
Quick Start
Compact Operating Instructions, 06/2017, A5E31805656-05
Power supply unit
Connecting the power supply
.
2
Appliance plug
to the power supply
5.1 Electrical connections
. Ensure that the
.
Connecting
41