Procedure To Remove Thermistor - Daikin RZQ71KBV1 Service Manual

Removal procedure, 3 hp class, outdoor unit, inverter, pair type
Hide thumbs Also See for RZQ71KBV1:
Table of Contents

Advertisement

Si281311

8. Procedure to Remove Thermistor

Procedure
Step
Remove the front panel 2,
the right side panel, and
the piping cover, following
the procedure indicated at
"Procedure to Remove
Outside Panels and
Related Parts".
Remove the outdoor air
1
thermistor, pulling
forward and then sliding
it to the right.
2
Pull out the discharge
pipe thermistor (∗1) by
picking and pulling out
the mounting spring.
Pull out the suction pipe
3
thermistor by pushing
the fixing part.
Since the heat
4
exchanger distributor
pipe thermistor is fixed
with the clamp plate,
pull the clamp plate
forward in order to
remove the thermistor.
Remove the
5
intermediate heat
exchanger thermistor
by pushing the fixing
part.
Pull out the liquid pipe
6
thermistor by pushing
the fixing part.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Thermistor
Discharge pipe
thermistor (R2T)
Suction pipe
thermistor (R3T)
Liquid pipe
thermistor (R6T)
∗1 The discharge pipe thermistor, the suction pipe
thermistor, the heat exchanger distributor
thermistor, and the intermediate heat exchanger
thermistor pipe are connected to the 1 common
connector. When replacing, you have to replace
the object all 4 thermistors at 1 time.
Procedure to Remove Thermistor
Points
Thermistor
Outdoor air
thermistor (R1T)
Intermediate heat
exchanger thermistor
(R5T)
Heat exchanger
distributor pipe
thermistor (R4T)
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rzq71kbv4aRq71kbv4a

Table of Contents