Si281311

10.Procedure to Remove Compressor

Procedure
Step
Collect the refrigerant.
Remove the outside
panels, their parts, and
the switch box, following
the procedure indicated at
"Removing Outside
Panels and Related Parts"
and other instructions.
Remove the fixing plate
1
for the stop valve after
removing the 5 screws.
2
Remove the sound
insulation (1).
Remove the terminal
3
cover, after pushing the
projective parts from
the both sides.
4
Remove the lead wire
from the terminal (2).
Pull out the sound
5
insulation by unwinding
the strings (2 locations).
Remove the nuts that
6
fix the compressor. (All
the equipments are
fixed with 3 nuts).
Cut off the brazing (2
7
locations).
Pull out the compressor
8
by lifting upward.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Fixing plate for the stop valve
Fixing nuts
Sound insulation (1)
Terminal cover
Brazings
Procedure to Remove Compressor
Be sure to confirm that the
refrigerant is completely
collected before starting the
work.
The color of each terminal
1 of the fixing nuts of the
compressor is located at the
outer side of the partition
plate.
Sound insulation (2)
String
Points
Rubber bush
Glass terminal
U
V
W
U: Red V: White W: Blue