Si281311
6. Procedure to Remove PCB Assy (3)
Procedure
Step
3. Remove the PCB assy
(A1P)
1
Remove the connectors
on the PCB.
Remove the 1 screw
2
that fixes the electric
component to the
mounting plate.
3
Pull out the PCB assy,
after removing from the
hooks at the both sides
(9 locations).
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Hooks
PCB assy (Retrieved)
X106A
X6A
X11A
X5A
X21A
DB502
X13A
X11A
X41A
X12A
LB
X17A
X25A X77A
X803A
X32A
Procedure to Remove PCB Assy (3)
Fixing screw
Hooks
IPM501
U
V
W
DB501
Q501
LC
D532
D531
NA
LA
E
Points
7