Download Print this page

Procedure To Remove Thermistor - Daikin RZQ100KV4A Removal Procedure

4/5/6 hp class

Advertisement

Si281316

6. Procedure to Remove Thermistor

Procedure
Step
Remove the top panel
and the front panel (2)
and side panel
accordance with the
Procedure to remove
Outside Panels.
Pull out the outdoor air
1
thermistor to the front,
and then slide this
thermistor to the right to
remove it.
Pinch the mounting
2
spring that fixes the
discharge pipe
thermistor to pull out
this thermistor.
3
Press the fixing section
of the suction pipe
thermistor to pull out
this thermistor.
Pull the fixing bracket of
4
the heat exchanger's
distribution pipe
thermistor to the front,
and then remove this
thermistor.
5
Press the fixing section
of the intermediate heat
exchanger thermistor to
pull out this thermistor.
6
Press the fixing section
of the liquid pipe
thermistor to pull out
this thermistor.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Thermistor
Discharge pipe
thermistor (R2T)
Mounting
spring
Thermistor
Suction pipe
thermistor (R3T)
Mounting
spring
Thermistor
Liquid pipe
thermistor (R6T)
1
The heat exchanger's distribution pipe thermistor,
intermediate heat exchanger thermistor, and liquid pipe
thermistor are jointed together with a single connector.
Consequently, these 3 thermistors should be replaced at
the same time.
Procedure to Remove Thermistor
Points
Thermistor
Outdoor air thermistor
Intermediate heat
exchanger thermistor
Heat exchanger distribution
pipe thermistor (R4T)
(R1T)
Thermistor
(R5T)
7

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Rzq125kv4aRzq150kv4aRzq160kv4a