Section 27.Tacacs+ Commands; Tacacs-Server Host - D-Link xStack DXS-3250 Cli Manual

L2 stackable gigabit mngd. switch with optional 10gig uplinks
Hide thumbs Also See for xStack DXS-3250:
Table of Contents

Advertisement

D-Link CLI Reference Guide
Section 27. TACACS+ Commands

tacacs-server host

The tacacs-server host Global Configuration mode command specifies a TACACS+ host. To delete the specified
name or address, use the no form of this command.
Syntax
tacacs-server host {ip-address | hostname} [single-connection] [port port-number] [timeout timeout] [key key-
string] [source source] [priority priority]
no tacacs-server host {ip-address | hostname}
Parameters
ip-address — IP address of the TACACS+ server.
hostname — Host name of the TACACS+ server. (Range: 1 - 158 characters)
single-connection — Indicates a single-connection. Rather than have the device open and close a TCP
connection to the daemon each time it must communicate, the single-connection option maintains a single
open connection between the device and the daemon.
port-number — Specifies a server port number. (Range: 0 - 65535)
timeout — Specifies the timeout value in seconds. (Range: 1 - 30)
key-string — Specifies the authentication and encryption key for all TACACS+ communications between the
device and the TACACS+ server. This key must match the encryption used on the TACACS+ daemon. To
specify an empty string, enter "". (Range: 0 - 128 characters)
source — Specifies the source IP address to use for the communication. 0.0.0.0 indicates a request to use
the IP address of the outgoing IP interface.
priority — Determines the order in which the TACACS+ servers are used, where 0 is the highest priority.
(Range: 0 - 65535)
Default Configuration
No TACACS+ host is specified.
If no port number is specified, default port number 49 is used.
If no host-specific timeout, key-string or source value is specified, the global value is used.
If no TACACS+ server priority is specified, default priority 0 is used.
Command Mode
Global Configuration mode
User Guidelines
Multiple tacacs-server host commands can be used to specify multiple hosts.