In Emulate mode, the user can create configuration files and presets as though a device
was connected, except for any actions that require a direct connection to the device or
information that is stored only on the device. Once the offline configuration is complete, the
user can either switch to Live mode and push the configuration to the device, or save the
configuration file to be loaded onto one or multiple devices at a later time.
NOTE: Not all menu options or actions are available in Emulate mode.
Live Mode
Connect to a device in Live mode to push or pull configurations between the device
and the host PC. In Live mode, changes made in DSP Configurator are directly applied
to the connected device. Upon leaving Live mode, the user is asked to confirm that
DSP Configurator should disconnect from the device.
Connecting Live to a Device
1.
Click the Live button in the menu bar of DSP Configurator (see figure 11,
Alternatively, select Tools>Connect to Device or press <F6> on the keyboard. The
Connect to device dialog box opens.
1
Figure 11.
NOTE: Select Connect... from the splash screen drop-down menu to connect to
a device and start DSP Configurator in Live mode.
Connect to the AXI using one of the following connection types:
2.
Dante — Click the Dante tab in the dialog box. Select the device from the
Dante Devices list. If the device has not been named, the default name consists of
the device model and the last 6 characters of the device MAC address (for example,
AXI02-0a690b).
NOTE: The Dante device and control computer must be on the same network.
3.
USB — Click the USB tab in the dialog box. Select the device from the USB Devices
drop-down menu.
NOTE: The host PC must be connected to the USB Config port.
When a connection with the device is established, the Synchronize with Device
dialog box opens. From the dialog box, one of two options can be selected:
Figure 12.
Live Button
Synchronize with Device Dialog Box
AXI 02 AT • DSP Configurator Software
).