TECHNICIAN SETUP MENU

Tech Settings
This feature will flash FILT in the
display after the elapsed run time
to remind the user to change the
Filter Change
filter. A setting of OFF will disable
Reminder
this feature.
This feature allows the installer to
change the calibration of the room
Room
temperature display. For example,
Temperature
if the thermostat reads 70° and
Calibration
you would like it to read 72° then
select +2.
This feature allows the installer to
select the minimum run time for the
compressor. For example: A setting
Minimum
of 4 will force the compressor to run
Compressor
for at least 4 minutes every time the
compressor turns on, regardless of
On Time
the room temperature.
12
LCD Will Show Adjustment Options
You can adjust the filter change
reminder from OFF to 2000
Next step
hours of runtime in 50 hour
increments. Tap the second
button from the top left side of
the thermostat to display the
Prev step
current filter elapsed runtime.
Next step
You can adjust the room
temperature display to read
3° above or below the factory
calibrated reading.
Prev step
You can select the minimum
compressor run time from OFF,
Next step
3, 4, or 5 minutes. If 3, 4, or 5
is selected, the compressor will
run for at least the selected time
before turning off.
Prev step
Default
OFF
0
OFF