RS9110
Op e ra t i o n M a n u a l

Advertisement

Table of Contents
loading

Summary of Contents for Robertshaw RS9110

  • Page 1 RS9110 Op e ra t i o n M a n u a l...
  • Page 3 RS9110 Table of Contents Page Table of Contents Caution Thermostat Operation Equipment damage hazard. Thermostat Quick Reference Do not operate the cooling Programming 8-10 system if the outdoor temperature is below 50°F Technician Setup Menu 11-15 (10°C) to prevent possible Terminal Designations compressor damage.
  • Page 4 THERMOSTAT OPERATION Room Set At Menu SLEEP SYSTEM ON AUTO COOL OFF HEAT LCD Screen Temperature Setpoint Buttons Fan Switch User Buttons System Switch...
  • Page 5 THERMOSTAT OPERATION Selecting OFF turns both heating LCD Screen See page 4 for details about and cooling off. this display readout. Temperature Setpoint Buttons Fan Switch Press the + or - buttons to select the Select ON or AUTO. ON will run the desired room temperature.
  • Page 6 THERMOSTAT QUICK REFERENCE Displays the user Days of the week Hold: Is displayed selected setpoint and time. when thermostat temperature. program is permanently Sun Mon Tue Wed Tech Set overridden. Min Com On Next Step Com Delay H e a t Low Battery Cool Swing Indicator:...
  • Page 7 THERMOSTAT QUICK REFERENCE Important: The low battery indicator is displayed when the 2x AAA batteries need to be replaced. Battery Door Information Replace with 2x AAA Alkaline Batteries. High quality Alkaline batteries are recommended. Use the finger bevel on the lower portion of the thermostat to open the easy access battery door.
  • Page 8 THERMOSTAT QUICK REFERENCE Temporary and Permanent Hold Feature (if using programming) Temporary Hold: The thermostat will display HOLD and RUNSCHED on the left of your screen when you press the  or key. If you do nothing, the temperature will remain at this setpoint until next time period. Your program setpoint will then replace your temporary setpoint.
  • Page 9 THERMOSTAT QUICK REFERENCE Filter Change Reminder If your HVAC contractor has configured the thermostat to remind you when the air filter needs to be changed, you will see FILTER in the display when your air filter needs to be changed. Resetting the filter change reminder: When FILTER reminder is displayed, you should change your air filter and reset the reminder by holding down the second button from the top left side of the thermostat for 3 seconds.
  • Page 10 PROGRAMMING Set Time 1. Press the MENU button. 2. Press SET TIME. 3. Day of the week will be flashing. Use the key to select the current day of the week. 4. Press NEXT STEP. 5. The current hour is flashing. Use the key to select the current hour.
  • Page 11 PROGRAMMING Set Program Schedule 5+1+1 or 7 Day To customize your program schedule, follow these steps: 1. Select HEAT or COOL with the system switch. Note: You have to program heat and cool separately. 2. Press the MENU button (If menu does not appear first press RUN SCHED). 3.
  • Page 12 PROGRAMMING Set Program Schedule 5+1+1 or 7 Day Saturday: Repeat steps 4 through 7 for the Saturday WAKE time period, LEAVE time period, RETURN time period, and for the Saturday SLEEP time period. Sunday: Repeat steps 4 through 7 for the Sunday WAKE time period, LEAVE time period, RETURN time period, and for the Sunday SLEEP time period.
  • Page 13 TECHNICIAN SETUP MENU 1. Press MENU button. 2. Press and hold TECH SET button for 3 seconds. 3. Configure the installer options as desired using the table on page 12. 4. Use the + OR - keys to change settings and the NEXT STEP or PREV STEP key to move from one option to another.
  • Page 14 TECHNICIAN SETUP MENU Tech Settings LCD Will Show Adjustment Options Default This feature will flash FILT in the You can adjust the filter change reminder from OFF to 2000 display after the elapsed run time Next step to remind the user to change the hours of runtime in 50 hour Filter Change filter.
  • Page 15 TECHNICIAN SETUP MENU Tech Settings LCD Will Show Adjustment Options Default The compressor short cycle delay Selecting ON will not allow the Next step protects the compressor from short compressor to be turned on for Compressor cycling. This feature will not allow 5 minutes after the last time the Short Cycle the compressor to be turned on for 5...
  • Page 16 TECHNICIAN SETUP MENU Tech Settings LCD Will Show Adjustment Options Default Next step Select F for Fahrenheit temperature F for Fahrenheit readout or select C for Celsius readout. C for Celsius For C Prev step You can select either a 12 or 24 hour Use the to select Next step...
  • Page 17 TECHNICIAN SETUP MENU Tech Settings LCD Will Show Adjustment Options Default You can configure this thermostat to have 7 Day, 5+1+1 programming or non-programmable. Note: If 7d is selected, in set schedule Next step Use the key to you will program all seven days select 7d for 7 Day, 5d for 5+1+1, Program individually.
  • Page 18 TERMINAL DESIGNATIONS RH ....24VAC Heating RC ....24VAC Cooling C ....Common 24VAC (system power supply) W ....HEAT Y ....COOL G ....FAN B ....REV VALVE HEAT O ....Cooling Activated Reversing Valve...
  • Page 20 Customer Service +1.800.304.6563 Technical Service +1.800.445.8299 Use Phone Year HVACCustomerService@robertshaw.com to Scan for Limited 352-00311-001 www.robertshaw.com • 352-00301-001 Warranty Info Warranty...