Thank you for purchasing a Robertshaw RS5000 Series programmable
thermostat. This user's manual will guide you through the setup of the
RS5110 single stage and the RS5220 two stage thermostats. The
thermostat should already be mounted and correctly wired. The default
settings will enable the thermostat to operate efficiently. Before making
any changes to the schedule read the section on Default Settings.
Features
• Pop-Up Wizard
• Automatic changeover
• Circulating fan
• Worry-Free memory retention
• Easy change battery
• Large back lit display
• Filter change reminder
• Low battery indicator
• Fahrenheit and Celsius displays
• EnergyStar™ compliant
• Dual power
• Adjustable 1
3.0 F degrees (0.5 C degrees to 1.5 C degrees)
• Accuracy within ±1 F degree
• Universal staging on multi-stage units
• Automatic heating shutdown if temperature exceeds 99°F (37°C)
• Keypad security lockout
• 4 events per day for heating and cooling
• 5-2 day scheduling
• User settable Hi and Lo temperature limits
• Vacation setpoint override
USERS MANUAL
st
stage temperature differential: 0.5 F degrees to
4110
RS
5110
RS
6 110
RS
1
4220
RS
5220
RS
6 220
RS
352-00056-001

Advertisement

Table of Contents
loading

Summary of Contents for Robertshaw RS4110

  • Page 1 USERS MANUAL Thank you for purchasing a Robertshaw RS5000 Series programmable thermostat. This user’s manual will guide you through the setup of the RS5110 single stage and the RS5220 two stage thermostats. The thermostat should already be mounted and correctly wired. The default settings will enable the thermostat to operate efficiently.
  • Page 2 Application The Robertshaw 5000 family of thermostats is designed to control gas, electric, oil, heat pump, and millivolt heating and electric cooling systems. The RS5110 is a single stage thermostat while the RS5220 is a two-stage thermostat. The RS5000 thermostats use 5-2 programming. This means the 5 weekdays will operate on one schedule and the 2 weekend days will operate on a second schedule.
  • Page 3: Installing Or Changing The Batteries

    Place the compartment back into the thermostat. When the batteries are low the thermostat will enter a low battery mode. Low battery mode has two levels. • LEVEL 1: The low battery icon will be displayed.
  • Page 4: Set Time And Day

    Set Time and Day To adjust the time and day settings press the SET TIME button. The hour will flash. If a button is not pushed within 10 seconds the thermostat returns to operation. To change the settings: 1. Use the 2.
  • Page 5: Emergency Heat

    Making Changes to the Programmed Settings Any setting can be changed when it is flashing by pushing If a button is not pushed within 10 seconds the thermostat returns to operation. The following buttons can be accessed from the front panel.
  • Page 6: To Make Changes In The Schedule

    To Make Changes in the Schedule: This thermostat can operate using a single setpoint by overriding the schedules. If you will be using this thermostat for single setpoint operation skip to Overriding the Schedule. Use the following table to document your schedule settings before editing the schedule on the thermostat.
  • Page 7: To Make Changes To Settings

    If a button is not pushed within 30 seconds the thermostat returns to operation. Use the Push EDIT SCHEDULE to move to minutes. Use the Push EDIT SCHEDULE to move to the heat or cool temperature setting. Use the Pressing will switch between cooling and heating.
  • Page 8 If the thermostat has been wired to enable this feature it will be displayed and the setting can be changed. DIFF = The differential keeps the thermostat from turning on for small changes in temperature. When in Fahrenheit the range is 0.5 to 3.0 degrees.
  • Page 9 DEDB = Deadband for auto changeover = the number of degrees that the room temperature can move away from the active setpoint until heating or cooling is called for. The larger the deadband the more the room temperature will vary. This can be from heat to cool or cool to heat.
  • Page 10: Security Lockout To Protect Settings

    2 degrees higher than the actual room temperature. Security Lockout to Protect the Settings The buttons on the front of the thermostat can be locked with a password. To create a password: 1. Press the for 5 seconds.
  • Page 11: Two Stage Systems

    If you have two stages, the thermostat will use only the first stage during this period. This is more efficient than waiting until the next event and then turning on both the first and second stages.
  • Page 12: Schedule Overrides

    Schedule Overrides When the thermostat is following a schedule, an override allows the thermostat to function with a single setpoint for a time period. A temporary override is entered as a setpoint for a number of hours. A vacation override is entered as a setpoint that is held for a number of days.
  • Page 13: Automatic Shutdown

    The thermostat will not display if the temperature is higher than 99°F (37°C) or lower than 32°F (0°C). If this happens, the display will show HI or LO. The thermostat continues to control heating and cooling and will display the room temperature...
  • Page 14: Troubleshooting

    Display shows HI or LO and room temperature is normal. If problems with thermostat cannot be resolved, contact: Technical Support: (800) 445-8299 Check wiring (see W W i i r r i i n n g g D D i i a a g g r r a a m m s s section in the Installation Manual).
  • Page 15: Five Year Limited Warranty

    Five Year Limited Warranty Invensys Controls warrants to the original contractor installer, or to the original consumer user, each new Robertshaw thermostat to be free from defects in materials and workmanship under normal use and service for a period of five (5) years from date of purchase. This...
  • Page 16 NOTES...
  • Page 17: Manual Del Usuario

    MANUAL DEL USUARIO Gracias por comprar un termostato programable Robertshaw Serie RS5000. El manual le ayudará a programar el modelo RS5110 de una sola etapa y el modelo RS5220 de dos etapas. El termostato debe estar instalado y conectado adecuadamente a la red de electricidad. Los ajustes por defecto permiten el funcionamiento eficiente del termostato.
  • Page 18 Aplicación La familia de termostatos Robertshaw 5000 está diseñada para controlar sistemas de refrigeración eléctrica y de calefacción de gas, electricidad, petróleo, bombas de calor y minivolt. El modelo RS5110 es un termostato de una sola etapa y el RS5220 es un termostato de dos etapas.
  • Page 19 Para instalar o cambiar las pilas Para retirar el compartimiento de las pilas, apriete suavemente los bordes estriados de ambos lados. El compartimiento de pilas de desprenderá del cuerpo del termostato. Coloque dos pilas AA según la indicación de polaridad que figura en el interior del compartimiento.
  • Page 20: Ajustes Por Defecto

    Para ajustar la hora y el día Para ajustar la hora y el día, pulse la tecla SET TIME (fijar la hora). La hora titilará en forma intermitente. Si no se pulsa ninguna tecla en 10 segundos, el termostato vuelve a ponerse en funcionamiento. Para cambiar los ajustes: 1.
  • Page 21 calefacción 62°F, refrigeración 85°F. El modo de operación será uno de los siguientes: El ajuste del ventilador es Auto. El teclado no tiene una contraseña de protección. Consulte en la sección del Asistente Desplegable Pop-Up Wizard del Manual de Instalación la lista completa de ajustes por defecto de fábrica y del contratista. Calefacción de emergencia Su sistema puede incluir la función calefacción de emergencia.
  • Page 22 Cuando los valores programados titilan se pueden modificar presionando las teclas termostato vuelve a ponerse en funcionamiento. Puede acceder a las siguientes teclas desde el panel delantero. START/STOP SCHEDULE (PROGRAMA INICIO/DETENCIÓN): cambia entre poner en funcionamiento un programa y el modo manual (sobrecontrol permanente).
  • Page 23 Pulse EDIT SCHEDULE (EDITAR PROGRAMA) para avanzar los minutos. Use las teclas si lo desea. Pulse EDIT SCHEDULE (EDITAR PROGRAMA) para pasar a fijar la temperatura de calefacción o refrigeración. Use las teclas Al pulsar pasará de calefacción a refrigeración o viceversa. Use las teclas - O - Pulse EDIT SCHEDULE (EDITAR PROGRAMA) para cambiar los valores de...
  • Page 24 light = luz del visor siempre prendida ”Y” o apagada ”n”. También llamada función de iluminación nocturna. Si el termostato ha sido conectado para habilitar esta función, aparecerá la indicación correspondiente y se podrá modificar el valor. DIFF = el diferencial evita que el termostato se ponga en funcionamiento ante cambios muy pequeños de temperatura.
  • Page 25 DEDB = margen de oscilación para conmutación automática = cantidad de grados que la temperatura ambiente puede alejarse del valor deseado hasta que empiece a funcionar el modo calefacción o refrigeración. Cuanto más amplio sea el margen de oscilación más variará...
  • Page 26 CHECK = recordatorio para realizar el mantenimiento del filtro. Por defecto, este control está desactivado. El temporizador funciona cuando el sistema se enciende y se puede finar en 0 (apagado) o en un valor de hasta 9900 horas. Cuando finaliza el tiempo, aparece en el visor CHECK FLTR.
  • Page 27 cualquier tecla aparecerá el ícono Para destrabar las teclas: 1. Pulse y mantenga oprimidas las teclas que el sistema le solicite la contraseña. 2. Ingrese los dígitos de la contraseña pulsando las teclas Pulse la tecla Pulse la tecla Si ingresa la contraseña equivocada, en el visor titilará la palabra “NO”...
  • Page 28 Modo Sobrecontrol Cuando se programa el termostato, se guardan los valores y el programa. El termostato cumplirá el programa salvo que se ingrese el Modo Sobrecontrol. El Modo Sobrecontrol tiene tres variantes. Modo Sobrecontrol permanente Pulse el START/STOP SCHEDULE (PROGRAMA INICIO/DETENCIÓN) hasta que la palabra SCHEDULE desaparezca del visor.
  • Page 29 sobrecontrol por vacaciones. El visor mostrará la temperatura ambiente y el valor deseado aparecerá intermitentemente con la cantidad de horas de funcionamiento que quedan en modo sobrecontrol. Pulse las teclas nuevo valor deseado para futuros usos en el modo sobrecontrol por vacaciones.
  • Page 30: Cierre Automático

    Cierre automático El termostato no mostrará valores de temperatura superiores a 99°F (37°C) o inferiores a 32°F (0°C). Si eso sucede, el visor mostrará HI o LO. El termostato sigue controlando la calefacción y la refrigeración y mostrará la temperatura cuando los valores se encuentren entre 32°F (0°C) y 99°F (37°C).
  • Page 31 Garantia Limitada de 5 años Invensys Control garantiza al instalador contratista original o al usuario original que cada termostato Robertshaw nuevo no tendrá defectos en componentes ni en construcción con el uso y mantenimiento normal durante un período de cinco (5) años desde la fecha de la compra. Esta garantía y nuestra responsabilidad no se aplican a las pilas ni a los...
  • Page 32 NOTES...