    RS9210 Table of Contents Page Table of Contents Caution Thermostat Operation Thermostat Quick Reference DO NOT SWITCH SYSTEM TO COOL Programming 8-10 IF THE TEMPERATURE IS BELOW 50°F (10°C). THIS CAN DAMAGE THE Installer Setup Menu 11-15 AIR CONDITIONING SYSTEM AND Terminal Designations CAUSE PERSONAL INJURY.
  • Page 4: Thermostat Operation

    THERMOSTAT OPERATION Room Set At Menu SLEEP HEAT AUTO COOL LCD Screen Temperature Set-Point Buttons Fan Switch User Buttons System Switch...
  • Page 5 THERMOSTAT OPERATION LCD Screen Temperature Set-Point Buttons See page 4 for detailed information. Press to select the Fan Switch desired temperature. Select ON or AUTO. ON will run the fan continuously. AUTO will cycle User Buttons the fan on only when the heating or Use these buttons to set up cooling system is on.
  • Page 6: Thermostat Quick Reference

    THERMOSTAT QUICK REFERENCE Days of the week Displays the user selected and time. set-point temperature. Hold: Is displayed when thermostat Sun Mon Tue Wed Thu program is overridden. Tech Set Min Com On Next Step Com Delay H e a t Low Battery Cool Swing Indicator:...
  • Page 7 THERMOSTAT QUICK REFERENCE Caution: When the battery icon appears, replace the alkaline AAA batteries immediately to avoid damage to your HVAC system. Freezing or overheating could occur. Battery Door Information Install two AAA Alkaline batteries into battery compartment. Be sure to match positive (+) ends of batteries with positive (+) battery terminals in the battery compartment.
  • Page 8 THERMOSTAT QUICK REFERENCE Temperature Adjustment (if Using a Program Schedule) Temporary Adjustment: You may temporarily change the desired temperature set-point by pressing either . The temperature will remain at this set-point until the next programmed WAKE, LEAVE, RETURN, or SLEEP event. The program schedule will then resume.
  • Page 9 THERMOSTAT QUICK REFERENCE Filter Change Reminder The thermostat can be configured to remind you when the air filter needs to be changed. The filter change reminder can be adjusted to up to 2000 hours in 50 hour increments. If the installer configured the thermostat to issue this reminder, FILTER will be displayed when it is time to change the air filter.
  • Page 10: Programming

    PROGRAMMING Set Time of Day and Day of Week 1. Press the MENU button. 2. Press SET TIME. 3. Day of the week will be flashing. Use to select the current day of the week. 4. Press NEXT STEP. 5. The current hour will be flashing. Use to select the current hour.
  • Page 11 PROGRAMMING Custom Programming This thermostat can be configured to have 7 Day or 5+1+1 programming. If 7 Day is selected, all seven days will need to be programmed individually. If 5+1+1 programming is selected, Monday–Friday will be programmed together and Saturday and Sunday will need to be programmed individually.
  • Page 12 PROGRAMMING Custom Programming 7. Press NEXT STEP. 8. Repeat steps 4 through 7 for the LEAVE time period, for the RETURN time period, and for the SLEEP time period for Monday–Friday (or Monday if in 7 Day mode). 9. Repeat steps 4 through 8 for the Saturday WAKE, LEAVE, RETURN, and SLEEP time periods, and then again for the Sunday WAKE, LEAVE, RETURN, and SLEEP time periods for the 5+1+1 program schedule, and for each day for the 7-day program schedule.
  • Page 13: Installer Setup Menu

    INSTALLER SETUP MENU 1. Press MENU. 2. Press and hold TECH SET button for 3 seconds. 3. Configure the installer options as desired using the table. 4. Use the to change settings and the NEW STEP or PREV STEP to move from one option to another. Note: Only press DONE key when you want to exit the Installer Setup Options.
  • Page 14 INSTALLER SETUP MENU Settings Display Adjustment Options Default The filter change reminder can This setting will flash FILT in be adjusted from OFF to 2000 Next step the display after the elapsed hours in 50 hour increments. Filter Change run time to remind the user Press the second button from the Reminder to change the filter.
  • Page 15 INSTALLER SETUP MENU Settings Display Adjustment Options Default Next step The compressor short cycle Compressor delay setting will not allow the The compressor short cycle Short Cycle delay setting can be removed by compressor to be turned on for 5 selecting OFF.
  • Page 16 INSTALLER SETUP MENU Settings Display Adjustment Options Default Next step F for Fahrenheit Select F for Fahrenheit temperature F or C display or select C for Celsius display. C for Celsius Prev step Next step 12 or 24 Hour Select a 12 or 24 hour clock setting. select 12 or 24 hour clock.
  • Page 17 INSTALLER SETUP MENU Settings Display Adjustment Options Default This thermostat can be configured to have 7 Day, 5+1+1 programming or be non-programmable. Next step If 7 Day is selected, in Set Time all seven days will need to be programmed individually. Program to select 7d for 7 Day, 5d If 5+1+1 programming is selected,...
  • Page 18: Terminal Designations

    TERMINAL DESIGNATIONS W2....Auxiliary heat relay Y .......Compressor relay G ......Fan relay O ...... Heat pump reversing valve energized in cooling R ......24VAC Power C ......Common wire from system transformer B ...... Heat pump reversing valve energized in heating W/E ....Emergency heat relay Note: In many heat pump systems without an emergency heat relay, a jumper can be installed between E and W2 to turn the thermostat into a single stage control for...
  • Page 20 Customer Service +1.800.304.6563 Technical Service +1.800.445.8299 Use Phone Year HVACCustomerService@robertshaw.com to Scan for Limited www.robertshaw.com • 352-00301-001 352-00312-001 Rev. B Warranty Info Warranty © 2021 Robertshaw Controls Company. Robertshaw is a trademark of Robertshaw Controls Company. ®...