Physical Data - Bryant 580J*08--14D Service And Maintenance Instructions

(2-compressor) nominal 7.5 to 12.5 tons with puron (r-410a) refrigerant
Table of Contents

Advertisement

Physical Data

Gas Connection
# of Gas Valves
Nat. gas supply line press (in. w.g.)/(PSIG)
LP supply line press (in. w.g.)/(PSIG)
Heat Anticipator Setting (Amps)
Natural Gas Heat, Liquid Propane Heat
# of stages / # of burners (total)
Connection size
Rollout switch opens / Closes
Temperature rise (min/max)
# of stages / # of burners (total)
Connection size
Rollout switch opens / Closes
Temperature rise (min/max)
# of stages / # of burners (total)
Connection Size
Rollout switch opens / Closes
Temperature rise (min/max)
APPENDIX II. PHYSICAL DATA (cont.)
(Heating)
580J**08
1
4--- 13 / 0.18--- 0.47
11--- 13 / 0.40--- 0.47
1st stage
0.14
2nd stage
0.14
1 / 3
1/2" NPT
195 / 115
20 --- 50
2 / 4
3/4" NPT
195 / 115
35 --- 65
2 / 5
3/4" NPT
195 / 115
45 --- 75
580J**12
1
4--- 13 / 0.18--- 0.47
11--- 13 / 0.40--- 0.47
0.14
0.14
2 / 4
3/4" NPT
195 / 115
25 --- 65
2 / 5
3/4" NPT
195 / 115
30 --- 65
2 / 5
3/4" NPT
195 / 115
35 --- 70
74
7.5 - - 12.5TONS
580J**14
1
4--- 13 / 0.18--- 0.47
11--- 13 / 0.40--- 0.47
0.14
0.14
2 / 4
3/4" NPT
195 / 115
25 --- 65
2 / 5
3/4" NPT
195 / 115
25 --- 65
2 / 5
3/4" NPT
195 / 115
35 --- 70

Advertisement

Table of Contents
loading

This manual is also suitable for:

580j*08-14f

Table of Contents