Standard Features; Model Number Nomenclature; Physical Data - Bryant 126B Series Product Data

Preferred series with puron refrigerant 1-1/2 to 5 nominal tons
Hide thumbs Also See for 126B Series:
Table of Contents

Advertisement

1
2
3
N
N
N
1
2
6
Product
Tier
SEER
Family
1=AC
2=
6=16
Legacy
SEER
the environmentally sound refrigerant
Feature
Puron Refrigerant
Maximum SEER *
Scroll Compressor
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Long Line capability
Low Ambient capability with Kit
High Pressure Switch
Low Pressure Switch
Compressor Sound Blanket
Louvered Coil Guard
* With approved combinations
X = Standard
UNIT SIZE --- VOLTAGE, SERIES
Operating Weight lb (kg)
Shipping Weight lb (kg)
Compressor Type
REFRIGERANT
Control
Charge lb (kg)
COND FAN
Air Discharge
Air Qty (CFM)
Motor HP
Motor RPM
COND COIL
Face Area (Sq ft)
Fins per In.
Rows
Circuits
VALVE CONNECT. (In. ID)
Vapor
Liquid
REFRIGERANT TUBES (In. OD)
Rated Vapor*
Max Liquid Line
* Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation.
{ See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables.

MODEL NUMBER NOMENCLATURE

4
5
6
A
A/N
N
B
N
A
Major
Voltage
Variations
Series
B=Puron
N=
A =
208 ---230 ---1
Standard
or
208/230 ---1
Use of the AHRI Certified
TM Mark indicates a
manufacturer's
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.

STANDARD FEATURES

PHYSICAL DATA

0018--- A
024--- A
136 (61.7)
163 (73.9)
163 (73.9)
198 (89.8)
4.60 (2.09)
6.00 (2.72)
1881
2614
1/12
1/10
1100
800
11.50
15.10
25
25
1
1
3
4
3/4
3/4
3/8
3/8
3/4
7
8
9
N
N
N
0
3
6
Cooling Capacity
ISO 9001:2000
REGISTERED
018
024
030
X
X
X
16.0
16.0
16.5
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
030--- A
036--- A
167 (75.7)
180 (81.6)
204 (92.5)
219 (99.3)
Scroll
Puron (R---410A)
TXV (Puron Hard Shutoff)
6.81 (3.09)
7.00 (3.18)
Propeller Type, Direct Drive
Vertical
2614
3223
1/10
1/12
800
800
17.20
17.60
25
25
1
1
4
4
3/4
7/8
3/8
3/8
3/8
2
10
11
12
A/N
A/N
N
0
0
0
Open
Open
Open
0=
0=
0=
Not
Not
Not
Defined
Defined
Defined
This product has been designed and manufactured to
meet Energy Star® criteria for energy efficiency when
matched with appropriate coil components. However,
proper refrigerant charge and proper air flow are critical
to achieve rated capacity and efficiency. Installation of
this product should follow all manufacturing refrigerant
charging and air flow instructions. Failure to confirm
proper charge and air flow may reduce energy
efficiency and shorten equipment life.
036
042
048
X
X
X
16.5
16.0
16.0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
042--- A
048--- A
234 (106.1)
248 (112.5)
281 (127.5)
291 (132.0)
8.62 (3.91)
10.50 (4.76)
3810
4046
1/5
1/4
800
800
25.15
20.10
25
20
1
2
6
7
7/8
7/8
3/8
3/8
7/8
14
A
A
Minor
Series
A =
Original
Series
060
X
16.0
X
X
X
X
X
X
X
X
X
X
X
060--- A
337 (152.9)
372 (188.7)
14.50 (6.58)
Vertical
4046
1/4
800
30.15
20
2
8
7/8
3/8
1 1/8
3/8