580J*08--14D
Service and maintenance instructions
Bryant 580J*08--14D Service And Maintenance Instructions page 80
(2-compressor) nominal 7.5 to 12.5 tons with puron (r-410a) refrigerant
Hide thumbs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
page
of
85
Go
/
85
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
580J*08D,F
VOLTAGE
COMP (Cir 1)
RANGE
V ---Ph---Hz
RLA
MIN MAX
208--- 3--- 60
187
253
13.6
230--- 3--- 60
187
253
13.6
460--- 3--- 60
414
506
6.1
575--- 3--- 60
518
633
4.2
580J*12D,F
VOLTAGE
COMP (Cir 1)
RANGE
V ---Ph---Hz
RLA
MIN MAX
208--- 3--- 60
187
253
15.6
230--- 3--- 60
187
253
15.6
460--- 3--- 60
414
506
7.7
575--- 3--- 60
518
633
5.8
580J*14D,F
VOLTAGE
COMP (Cir 1)
RANGE
V ---Ph---Hz
RLA
MIN MAX
208--- 3--- 60
187
253
19.0
230--- 3--- 60
187
253
19.0
460--- 3--- 60
414
506
9.7
575--- 3--- 60
518
633
7.4
ELECTRICAL INFORMATION
2 ---Stage Cooling
COMP (Cir 2)
OFM (ea)
LRA
RLA
LRA
WATTS
83
13.6
83
325
83
13.6
83
325
41
6.1
41
325
33
4.2
33
325
2 ---Stage Cooling
COMP (Cir 2)
OFM (ea)
LRA
RLA
LRA
WATTS
110
15.9
110
325
110
15.9
110
325
52
7.7
52
325
39
5.7
39
325
2 ---Stage Cooling
COMP (Cir 2)
OFM (ea)
LRA
RLA
LRA
WATTS
123
22.4
149
1288
123
22.4
149
1288
62
10.6
75
1288
50
7.7
54
1288
Max
FLA
TYPE
WATTS
AMP Draw
STD
1448
MED
2278
1.5
HIGH
4400
STD
1448
MED
2278
1.5
HIGH
4400
STD
1448
MED
2278
0.8
HIGH
4400
STD
1379
0.6
MED
3775
HIGH
4400
Max
FLA
TYPE
WATTS
AMP Draw
STD
2120
MED
3775
1.5
HIGH
4400
STD
2120
MED
3775
1.5
HIGH
4400
STD
2120
MED
3775
0.8
HIGH
4400
STD
1390
0.6
MED
3775
HIGH
4400
Max
FLA
TYPE
WATTS
AMP Draw
STD
2615
MED
3775
6.2
HIGH
4400
STD
2615
MED
3775
6.2
HIGH
4400
STD
2615
MED
3775
3.1
HIGH
4400
STD
3775
MED
3775
2.5
HIGH
4400
80
7.5 Tons
IFM
Max
EFF at Full Load
FLA
5.5
80%
7.9
81%
15.0
81%
15.0
5.5
80%
7.9
81%
15.0
81%
15.0
2.7
80%
3.6
81%
7.4
81%
2.5
80%
2.9
81%
5.9
81%
10 Tons
IFM
Max
EFF at Full Load
FLA
5.5
80%
10.5
81%
10.0
15.0
81%
15.0
5.5
80%
10.5
81%
10.0
15.0
81%
15.0
2.7
80%
4.6
81%
7.4
81%
2.1
80%
2.9
81%
5.9
81%
12.5 Tons
IFM
Max
EFF at Full Load
FLA
7.9
81%
10.5
81%
10.0
15.0
81%
15.0
7.9
81%
10.5
81%
10.0
15.0
81%
15.0
3.6
81%
4.6
81%
7.4
81%
2.9
81%
2.9
81%
5.9
81%
5.2
7.5
5.2
7.5
2.6
3.4
7.4
2.4
2.8
5.6
5.2
5.2
2.6
4.4
7.4
2.0
2.8
5.6
7.5
7.5
3.4
4.4
7.4
2.8
2.8
5.6
Table of
Contents
Previous
Page
Next
Page
1
...
77
78
79
80
81
82
83
84
Show Quick Links
Quick Links:
Table of Contents
Unit Arrangement and Access
Supply Fan (Blower) Section
Gas Heating System
Wiring Diagrams
Appendix I. Model Number Significance
Appendix II. Physical Data
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Related Manuals for Bryant 580J*08--14D
Air Conditioner Bryant 580J*04--12 Service And Maintenance Instructions
Nominal 3 to 10 tons with puronr (r410a) refrigerant (73 pages)
Air Conditioner Bryant 580J***(D Submittal Data
Single package rooftop gas heating/electric cooling unit two stage cooling capacity control with novation coil sizes 08, 12, 14 with puron (r--410a) refrigerant (8 pages)
Air Conditioner Bryant 580J***D series Installation Instructions Manual
Single package rooftop gas heating/electric cooling unit with novation coil sizes 17, 20, 24, 28 with puron (r-410a) refrigerant (32 pages)
Air Conditioner Bryant 580J*16D Series Electrical Data Supplement
Single package rooftop, gas heating/electric cooling unit with puron r--410a) refrigerant size: 16 (4 pages)
Air Conditioner Bryant LEGACY 580J*16 Series Installation Instructions Manual
Single package rooftop with gas heat/electric cooling (64 pages)
Air Conditioner Bryant LEGACY 580J Product Data
Gas heat/electric cooling packaged rooftop 3 to 15 nominal tons (95 pages)
Air Conditioner Bryant 580J Submittal Data
Single package rooftop gas heating/electric cooling horizontal air flow units, with puron (r-410a) refrigerant 15, 17.5, 20, 25 tons (model sizes 18, 21, 25, 29) (14 pages)
Air Conditioner Bryant 580J Submittal Data
Single package rooftop gas heating/electric cooling unit sizes 04-07 with puron (r-410a) refrigerant (8 pages)
Air Conditioner Bryant 582K Installation Instructions Manual
3 to 12.5 tons (48/50lc 14 not included) accessory ultra low leak vertical economiser x (24 pages)
Air Conditioner Bryant 580J Installation, Start-Up And Service Instructions Manual
Variable frequency drive (vfd) factory-installed option 2-speed motor control for 2-stage cooling rooftop units (64 pages)
Air Conditioner Bryant 580J*04A Installation Instructions Manual
580j legacy series single package rooftop with gas heat/electric cooling sizes 04, 05, 06, 07 (53 pages)
Air Conditioner Bryant 580J Series Installation Instructions Manual
Single package rooftop, gas heating/electric cooling vertical air flow unit with puron (r-410a) refrigerant (52 pages)
Air Conditioner Bryant 580J D17 Service And Maintenance Instructions
Gas heat packaged rooftop nominal 15 to 27.5 tons with puron r-410a refreigerant (92 pages)
Air Conditioner Bryant 580F User's Information Manual
Single package rooftop gas heating/electric cooling units (7 pages)
Air Conditioner Bryant DuraPac 580F Series Installation, Start-Up And Service Instructions Manual
Single package rooftop gas heating/electric cooling units (70 pages)
Air Conditioner Bryant 581A/B Product Information Manual
Durapac and durapac plus series commercial single package rooftop units gas heating/electric cooling units (268 pages)
Related Products for Bryant 580J*08--14D
Bryant LEGACY 580J*08N Series
Bryant LEGACY 580J*08P Series
Bryant LEGACY 580J*08D Series
Bryant LEGACY 580J*08F Series
Bryant LEGACY 580J*08K Series
Bryant 580J*04--12
Bryant 580J*06B
Bryant 580J*07A
Bryant 580J*06C
Bryant 580J*07C
Bryant 580J*07J
Bryant 580J*07G
Bryant 580J*05A
Bryant LEGACY 580J*09N Series
Bryant LEGACY 580J*09P Series
Bryant LEGACY 580J*09DF Series
This manual is also suitable for:
580j*08-14f
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL