Operation; Operating Checklist - Graco 333013B Instructions - Parts Manual

Pro xp auto waterborne aa spray gun
Table of Contents

Advertisement

Operation

Operating Checklist

Check the following list daily, before starting to operate the system, to help ensure you of safe, efficient operation.
All operators are properly trained to safely operate an automatic electrostatic waterborne air spray system as
instructed in this manual.
All operators are trained in the Fluid Voltage Discharge and Grounding Procedure on page 22.
All operators are trained in the Pressure Relief Procedure on page 22.
The electrostatics are turned off and system voltage is discharged according to the Fluid Voltage Discharge
and Grounding Procedure, page 22, before any person enters the isolation enclosure, before cleaning, and
before performing any maintenance or repair.
The warning sign provided with the gun is mounted in the spray area where it can be easily seen and read by
all operators.
The system is thoroughly grounded and the operator and all persons entering the spray area are properly
grounded. See Grounding on page 18.
The Graco Waterborne Fluid Hose is in good condition with no cuts or abrasions. Replace hose if damaged.
The condition of the gun's electrical components has been checked as instructed in Electrical Tests on page
29.
All fluid hose connections are tight.
Ventilation fans are operating properly.
Workpiece hangers are clean and grounded.
All debris, including flammable fluids and rags, is removed from the spray area.
All conductive objects in the spray area are electrically grounded and the floor of the spray area is electrically
conductive and grounded.
All flammable fluids in the spray booth are in approved, grounded containers.
The manifold exhaust tubes have been checked for the presence of any fluid as instructed in Check for Fluid
Leakage on page 28.
Fluids used must meet the following flammability requirements:
FM, FMc Approved:
Material does not sustain burning in accordance with the Standard Test Method for Sustained Burning of Liquid
Mixtures, ASTM D4206.
CE-EN 50059 Compliant:
Materials which cannot be ignited, in any mixture with air, by an energy source of less than 500mJ.
333013B
Operation
21

Advertisement

Table of Contents
loading

Table of Contents